Drainage Piping Work; Electrical Work - Mitsubishi Electric SEZ-KA35 Installation Manual

Air-conditioners
Hide thumbs Also See for SEZ-KA35:
Table of Contents

Advertisement

6. Drainage piping work

Fig. 6-1

7. Electrical work

(1) SEZ-KA35, KA50, KA60, KA71VA
B
S1
S2
D
For Power supply
D
For Power
supply
B
A
E
C
Fig. 7-1
6
A
B
H
: 50 mm or more
1
H
: 1/2 H
2
1
A
S1
S2
S3
1
2
S3
C
A Indoor unit
B Outdoor unit
C Wired remote controller
D Main switch/fuse
E Grounding
A
6.1. Drainage pipe connection (Fig. 6-1)
Indoor unit's drainage pipe
• The drainage pipe should be arranged so that the discharge end is lower than the
other end, as shown in the figure opposite.
• Place the trap outside the unit.
• After connecting the drainage pipe, make sure that water is discharged properly
and that there are no leaks.
A Drainage piping connection 1 RP male.
B Trap
Outdoor unit drainage pipe connection
When drainage piping is necessary, use the drain pan (supplied as an option).
or more
7.1. Precautions (Fig. 7-1)
Electrical specification
Power supply
(1 phase ~/N, 230V,
50Hz)
• The compressor will not operate unless the power supply phase connection is cor-
rect.
• Grounding protection with a no-fuse breaker (earth leakage breaker [ELB]) is usu-
ally installed for D.
• The connection wiring between the outdoor and indoor units can be extended up to
a maximum of 50 meters, and the total extension including the crossover wiring
between rooms is a maximum of 80 m.
A switch with at least 3.5 mm contact separation in each pole shall be provided by the
air conditioner installation.
* Label each breaker according to purpose (heater, unit etc.).
A
Input capacity Main Switch/Fuse (A)
SEZ-KA35
SEZ-KA50
SEZ-KA60
10
20
20
SEZ-KA71
20

Advertisement

Table of Contents
loading

Table of Contents