Air King BFQ Series Operating Manual

Air King BFQ Series Operating Manual

Exhaust fan
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT INSTRUCTIONS -
BFQ, BFQW Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
210572021 Rev. L 5-14
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
CAUTION:
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install wall mounted fans inside the shower area.
WARNING:
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BFQ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Air King BFQ Series

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL BFQ, BFQW Series Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS Snap the fan body into the bracket (Figure 4). The fan can be snapped into position with the duct collar facing to the left or the right CAUTION: depending which is most convenient. MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.
  • Page 3: Completing The Installation

    CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. Run wiring from an approved wall switch carrying the appropriate rating.
  • Page 4: Troubleshooting Guide

    SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS.
  • Page 5: Limited Warranty

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Qty. Description Replacement Part # Fan Housing 5S2205001 Motor - BFQ110 5S2205008 Damper Assembly - BFQ 5S2299054 Motor - BFQ140 5S2299002 Damper Assembly - BFQW 5S2299055 Clip 5S2205009 Receptacle 3P 5S2205004 Motor Bracket 5S2299003 Wire Cover 5S2205005...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Série BFQ et BFQW Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION ATTENTION : POUR UNE INSTALLATION APPROPRIÉE, UTILISEZ UN MINIMUM DE 4 VIS SITUÉES DANS LES TROUS LES PLUS PROCHES ATTENTION : VOUS ASSURER QUE L’ALIMENTATION DES PLAQUES DE PLÂTRE. EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER Fixer par pression le bâti du ventilateur dans le support (Figure 4).
  • Page 9 SECTION 3 ATTENTION : TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITES EN CONFORMITÉ AVEC LES CODES ÉLECTRIQUES LOCAUX OU Construction Existante - Modèles BFQ NATIONAUX. SI VOUS N’ÊTES PAS FAMILIER AVEC LES MÉTHODES Positionner le cabinet contre la solive ou le montant et tracer le D’INSTALLATION DE CÂBLAGE ÉLECTRIQUE, RECOURREZ AUX SERVICES contour du cabinet sur le matériau du mur / plafond.
  • Page 10: Guide De Dépannage

    SECTION 7 Installer la grille en pressant ensemble les deux extrémités des ressorts et en les installant dans les fentes du châssis du ventilateur. Use and Care Pousser la grille en position (Figure 12). ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.
  • Page 11: Garantie Limitée

    Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Cabinet du ventilateur 5S2205001 Moteur - BFQ110 5S2205008 Assemble du Clapet - BFQ 5S2299054 Moteur - BFQ140 5S2299002 Assemble du Clapet - BFQW 5S2299055 Clip 5S2205009...