Wall Fitting - Electrolux EFT 605 Instruction Book

Cooker hood
Hide thumbs Also See for EFT 605:
Table of Contents

Advertisement

Clearance Height
A minimum clearance height of 650mm
(25 1/2 ") is required when installed above a
built-in electric hob, or 700mm (27 1/2 ") when
installed above a built-in gas hob.
A minimum clearance height of 685mm (27")
is required when installed above a slot-in
electric oven, or 787mm (30 1/2 ") when
installed above a slot-in gas oven.
When installed between adjoining wall
cabinets, the wall cabinets must not overhang
the hob and the distance between the
underside of the cabinet and the worktop
must be 450mm. If the height of the wall
cabinet is less than 450mm a gap of 50mm
must be maintained either side of the hob.
This cooker hood must not be installed above
a cooking appliance with a high level grill.
Unpacking
The fittings supplied to install this cooker
hood can be found with the instruction book
inside the packaging and consists of the following:
Wall/suspended fixing template
Plastic rawl plugs (2)
Fixing screws (4)

Wall Fitting

The cooker hood is fitted to the wall using the
keyhole slots in the back of the hood.
1.
Mark the position on the wall for the two 8mm
dia screw holes (A) as illustrated in the
drawing opposite at 568mm.
2.
Check that the hole distances are correct and
are level using a spirit level.
3.
At this stage it is important to allow 25mm (1")
clear space above the cooker hood to enable it
to be hooked onto the screws and for
subsequent removal for decorating or
servicing.
4.
Insert the screws and tighten to a distance of
5mm.
A: Built-in Electric Hob:
B: Built-in Gas hob:
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker:
12
Hob
650mm minimum clearance
700mm minimum clearance
787mm minimum clearance