MAINTENANCE AND SERVICE

A:
ROUTINE
MAINTENANCE
HOME OWNER
Other than remembering to arrange for
the annual professional servicing of the
furnace by the service or installation
contractor, the most important routine
service performed by the homeowner is
to maintain the air filter or filters. A dirty
filter can cause the furnace to over-heat,
fail to maintain indoor temperature during
cold weather, increase fuel consumption
and cause component failure.
The furnace filter(s) should be inspected,
cleaned
or
replaced
monthly.
furnace is factory equipped with a semi-
permanent type filter. If the filter is
damaged, replace with filters of the same
size and type.
During the routine service, inspect the
general condition of the furnace watching
for signs of oil leaks in the vicinity of the
oil burner, soot forming on any external
part of the furnace, soot forming around
the joints in the vent pipe, etc. If any of
these conditions are present, please
advice
your
service
or
contractor.
B:
ANNUAL
SERVICE
CONTRACTOR
THE
COMBUSTION
(FIREPOT) IS FRAGILE. USE CARE
WHEN INSPECTING AND CLEANING
THIS AREA.
The heat exchanger should be inspected
periodically and cleaned if necessary. If
cleaning
is
necessary,
POWER
TO
THE
FURNACE
remove the burner. Using a stiff brush
with a wire handle, brush off scale and
soot from inside the drum and flue pipe.
To clean the radiator, remove the round
cover or covers on the inner radiator
access pipes located on the front panel
between the oil burner and the flue pipe.
A wire brush can be used to loosen dirt
and debris on the inside surfaces of the
radiator. Clean out all accumulated dirt,
soot and debris with a wire handled
brush and an industrial vacuum cleaner.
Replace the clean-out covers.
Most
circulating
fan
permanently lubricated by the motor
manufacturer. These motors will have no
oil ports. If the blower motor does
contain oil ports, under normal operating
conditions it will not require oiling for the
first two years. Oil sparingly; a few drops
in each oil port with SAE 20 non-
detergent oil. Oiling is most easily done
BY
with a "tele-spout" oiler. This oiler has a
long flexible plastic spout. DO NOT
OVER-LUBRICATE. Excess oil may
result in premature electric motor failure.
Inspect the blower fan. Clean it if
necessary.
Oil Burner Maintenance: Follow the
instructions
manufacturer.
manufacturer's instructions supplied with
furnace). The oil burner nozzle should be
replaced annually. We recommend that
the oil filter be changed on an annual
The
basis.
The venting system should be cleaned
and inspected for signs of deterioration.
Replace pitted or perforated vent pipe
and
fittings.
regulator should open and close freely.
All electrical connections should be
checked to ensure tight connections.
Safety controls such as the high limit
controls
functionality. The fan control functions
should be checked to ensure that all fan
installation
speeds are operating properly.

OPERATING INSTRUCTIONS

BY
Before Lighting
Open all supply and return air registers
and grilles.
CHAMBER
Open all valves in oil pipes.
Turn on electric power supply.
To Light Unit
Set
the
temperature to call for heat. The burner
SHUT
OFF
will start. NOTE: If the furnace has been
and
off for an extended period of time, it may
be necessary to press the RESET button
on the primary combustion control relay,
(once only). If pressing the reset button
does not start the furnace, refer to
Appendix C, Troubleshooting.
15 seconds after the thermostat calls for
heat, the electronic fan timer board on
time delay starts. After the delay time is
complete. the circulation fan will start.
The furnace will continue to run until the
thermostat call for heat is satisfied.
Set
the
motors
are
temperature. The oil burner will stop.
The air circulation blower will continue to
run for the set time after the oil burner
has stopped, depending on the dip
switch settings.
of
the
oil
burner
(See
oil
burner
The
barometric
draft
should
be
tested
thermostat
above
room
thermostat
below
room
11
To Shut Down Unit
Set the thermostat to the lowest possible
setting.
Set
the
installed) in the Electrical Power Supply
Line to "OFF".
NOTE: If the furnace is to be shut
down for an extended period of time,
close the oil supply valve to the oil
burner.
DO NOT ATTEMPT TO START THE
BURNER WHEN EXCESS OIL HAS
ACCUMULATED,
FURNACE IS FULL OF VAPOUR, OR
WHEN THE COMBUSTION CHAMBER
IS
VERY
HOT.
GARBAGE
OR
FURNACE,
AND
PAPER OR RAGS AROUND THE UNIT.
for
151B0801 R5 3/28/2006
manual
switch
(if
WHEN
THE
NEVER
BURN
PAPER
IN
THE
NEVER
LEAVE