Furnace Installation Set-Up - Nordyne O4HD-091A-12-FA Installation Instructions Manual

Oil-fired warm air furnace (upflow or horizontal models)
Table of Contents

Advertisement

Fig. 5: Checking Over-Fire Draft.
SMOKE TEST NOTE:
If oily or yellow smoke spots are found
on the smoke test filter paper, it is
usually a sign of unburned fuel. This
indicates poor combustion. This type of
problem may be caused by excess draft,
excess air, or contaminated fuel. Do not
ignore this indicator.
STACK TEMPERATURE:
Stack temperature will vary depending
on fuel input, circulating air blower
speed, and burner set up, etc. In
general,
stack
temperature
typically range between 380°F to 550°F,
assuming that the combustion air is
approximately room temperature (65°F -
70°F).
In
general,
temperature indicates greater efficiency;
however,
excessively
temperature can lead to condensation
forming in the chimney and / or venting.
Sulphur and similar contaminants in the
fuel oil will mix with condensation to form
acids. Acids and resultant chemical salts
will cause rapid deterioration of the
chimney and venting components, and
may attack the furnace.
If the flue gases are below the range, it
may be necessary to slow down the
blower fan. If the flue gases are above
the range, the blower fan may require
speeding up. Stack temperature varies
directly with the system temperature rise.
System temperature rise is the difference
between the furnace outlet temperature
and
furnace
inlet
temperature
measured
in
the
vicinity
connection between the plenum take-offs
and the trunk ducts. Refer to the
appliance rating plate of model for
temperature rise range.
If the venting from the furnace to the
chimney is long, or exposed to cold
ambient
necessary to use L-Vent as the vent
connector to reduce stack temperature
loss
to
venting should be inspected annually to
ensure that it is intact.

FURNACE INSTALLATION SET-UP

The furnace must be set up as the final
step in the installation.
A) The oil burner must be set up
following the procedures outlined above.
B) The appliance rating plate should be
consulted for model temperature rise
ranges. To determine the temperature
rise, measure the supply air and return
air temperatures when the furnace has
reached steady state conditions. This is
the point at which the supply air
temperature stops increasing relative to
the return air temperature. The furnace
may have to run 10 to 15 minutes to
reach
measurements may be made with duct
thermometers or thermocouples used in
conjunction
temperature measurement capabilities.
The return air should be measured at a
point where the thermometer will be well
within the air stream near the furnace
return air inlet. Actual location is not
should
particularly
locations
readings could be affected by humidifier
bypass ducts, the inside radius of
lower
stack
elbows, etc.
low
stack
The supply air temperature should be
measured
thermometer will be well within the air
stream near the furnace supply air outlet.
Usually, the side mid-point of the supply
air plenum take-off is ideal, providing it is
out of the line of sight to the heat
exchanger. If the thermometer is within
the line of sight of the heat exchanger,
the supply air readings may be skewed
by radiant heat from the heat exchanger.
If the plenum take-off is unsuitable, the
supply air temperature may be measured
within the first 18 inches of the first
segment of supply air trunk duct.
If the temperature rise is outside the
recommended range, it may be adjusted
as
on
direct
of
the
selecting alternate circulation fan motor
speeds. If the temperature rise is too
high,
speed
temperatures,
it
may
prevent
condensation.
steady state conditions. The
with
multi-meters
critical;
however,
where
the
temperature
at
a
point
where
drive
equipped
units
the
fan
up.
10
temperature rise is too low, slow the fan
down.
C) Keep
in
temperature varies directly with the
be
temperature
temperature rise, the higher the stack
temperature will be, resulting in lower
The
efficiency. The lower the temperature
rise, the lower the stack temperature will
be, which, in some cases, may allow
condensation to form in the chimney and
other vent parts.
D) Test the high limit control to ensure
that it is operating correctly. This may be
done
by
temporarily
circulator fan heating wire or neutral
wire. Turn of electrical power to the
furnace before working with the motor
wires. Be sure to protect any removed
wires from shorting out on metal furnace
parts. If the high limit test is successful,
shut off the electrical power to the
furnace, restore the proper motor wiring.
Finally, restore power to the furnace.
E) Operate the furnace through a
minimum of three full heating cycles.
During this time, check for fuel oil leaks,
gross air leakage from the supply air
ductwork, unusual noises originating
anywhere within the heating system
with
which may cause some concern or
annoyance to the home owner, etc.
F)
Be sure that the homeowner is
familiar
with
homeowner should be aware of the
location of electrical circuit breaker or
avoid
fuse, the location of any electrical
switches controlling the furnace, the
location of the oil tank shut-off valve and
how
to
operate
homeowner should be informed where
the oil tank gauge is located and how to
the
read it.
It would be beneficial to review safety
issues with the home owner, such as the
danger of storing combustibles too close
to the furnace, hanging anything on the
furnace vent pipe, and especially the
dangers of indiscriminately pressing the
burner reset button.
IMPORTANT: Be sure that the home
owner knows where the burner reset
switch is located, and is aware that the
reset switch is not to be activated more
than once without a thorough look for the
cause of the problem, (lack of fuel, etc.).
Be sure that the homeowner knows
when to quit trying to start the furnace
by
during these conditions and who to call
for emergency service.
If
the
mind
that
the
stack
rise.
The
higher
the
removing
the
the
furnace.
The
the
valve.
The
151B0801 R5 3/28/2006