OPERATING TIPS
Temperature and Humidity Range
DB : DRY Bulb Temperature
WB : Wet Bulb Temperature
Maximum Temperature
Minimum Temperature
• If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of
the indoor unit, and drip onto the floor or other objects underneath.
• If the air conditioner is used under higher temperature conditioner than those listed, the build-in protection cir-
cuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used
under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to
water leakage and other damage.
• Do not use this unit for any purpose other than the Cooling, Heating, and Dehumidifying, and air-circulation of
rooms in ordinary dwellings.
SPECIFICATION
MODEL
TYPE
POWER
COOLING
CAPACITY
INPUT POWER
CURRENT
HEATING
CAPACITY
INPUT POWER
CURRENT
MAX. PRESSURE
SUCTION
DISCHARGE
REFRIGERANT
DIMENSIONS & WEIGHT
INDOOR UNIT
Height/Width/Depth
Weight
OUTDOOR UNIT
Height/Width/Depth
Weight
• The specifications listed in the above table were measured under the following conditions.
• Temperatures
Indoor Temp.
Outdoor Temp.
• Position of the AIRFLOW DIRECTION flap
For ADJUSTING THE DIRECTION OF AIR CIRCULATION on Page 9, use position w for COOLING and
position r for HEATING.
Cooling and Dry
Indoor
DB
WB
32
23
18
13
INDOOR UNIT
AST13PSA-W
HEAT&COOL MODEL (REVERSE CYCLE) INVERTER
COOLING
DB
WB
27
19
35
24
Outdoor
DB
WB
DB
43
26
10
––
230V to 50Hz
3.7 (Minimum 1.03 to Maximum 4.0) kW
1.48 (Minimum 0.35 to Maximum 1.82) kW
6.5 (Maximum 8) A
4.85 (Minimum 0.8 to Maximum 6.1) kW
1.61 (Minimum 0.33 to Maximum 2.28) kW
7.1 (Maximum 10) A
800kPa
2700kPa
R22 950g
280/815/179 mm
9kg (NET)
535/695/250 mm
34kg (NET)
[°C ]
HEATING
DB
WB
20
15
7
6
– 71 –
Heating
Indoor
Outdoor
WB
DB
30
––
24
2
––
– 5
OUTDOOR UNIT
AOT13PNA
[°C ]
WB
18
– 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aot13pna

Table of Contents