Line Voltage Conversion

WARNING:
Shock Hazard Operating personnel must not remove instrument covers.
Component replacement and internal adjustments must be made only by qualified
service personnel.

Open the Unit

Turn off ac power and disconnect the power cord from the unit.
Remove the four screws that secure the cover (use a #2 Pozi drive).
Slightly spread the bottom of the cover and pull it back to remove it from the unit.

Configure the Power Transformer

Locate the ac input wiring harness on the left side of the transformer.
Use a needlenose pliers and connect the ac input wiring harness according to the information in the
following figure:
white/red/grey
spare
jumper
white/red/grey
Figure D-1, Power Transformer AC Input Connections
grey
grey
jumper
white/red/grey
jumper
white/red/grey
jumper
D
grey
grey
69