Advertisement

Dividing a PS problem to the
output or regulation stage
with 2 voltages.
Measure voltages. Look up voltages
on chart below for the defect area.
1
2
1. Output volt
2. FdBk volt
@ w5713
at w5711
30Vdc
1.5Vdc
Lower than 30V
Higher than 1.5V
Lower than 30V
Lower than 1.5V
Higher than 30V
Higher than 1.5V
Higher than 30V
Lower than 1.5V
Slide # 31
Power Supply Block
Defect area
Normal Operation
Reg circuit (IC5801, Q5802)
Output Stage (IC5701,
T5701, D5702)
Output Stage (IC5701,
T5701, D5702)
Reg circuit (IC5801, Q5802)
for Stby, Pwr On, Isolation.
Plug In, Power ON Sequence
1.
Press Power ON
2.
Fan turns on - Starts Noisy
3.
Hello is displayed
4.
Last Mode used is displayed.
Outline
Models:
Wireless
SA-PT660
Mech
SA-PT760
Pwr Supply
SA-PT960
Protection
SA-PT1060
Audio
SH-FX67, 85