Dc Usage - Buffalo GEN1850 Instruction Manual

1850 surge watts portable generator
Hide thumbs Also See for GEN1850:
  • Faq (7 pages)
Table of Contents

Advertisement

SOME NOTES ABOUT POWER CORDS
Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to
the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly
higher rated wattage requirement.
Device Requirements
Amps
2.5
5
7.5
10
15
20
25
30
40
NR = Not Recommended.

DC Usage

The DC outlet is for using any 12 Volt DC device, up to 8.3 Amps.
NEVER attempt to jumpstart a car with this generator.
Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency.
GEN1850 1850 Surge Watts Portable Generator
Watts (120V)
Watts (240V)
300
600
600
1200
900
1800
1200
2400
1800
3600
2400
4800
3000
6000
3600
7200
4800
9600
Figure 6 - Maximum Extension Cord Lengths by Power Requirement
Max. Cord Length (ft) by Wire Gauge
#8 wire
#10 wire
#12 wire
NR
1000
600
NR
500
300
NR
350
200
NR
250
150
NR
150
100
175
125
75
150
100
60
125
65
NR
90
NR
NR
#14 wire
#16 wire
375
250
200
125
125
100
100
50
65
NR
50
NR
NR
NR
NR
NR
NR
NR
16