Ex. When the Set_ID wants lighting 1st person TV
> mpo0101
> 01mpo01
Command : " mpo0101" (mpo : Power / 01 : Set_ID / 01 : Power On)
Response : " 01mpo01" ( The Set_ID lights 01st person LCD&PDP)
When the Set_ID wants knowing the Power condition of 3rd person TV
> mpo03ff
> 03mpo01
Command : " mpo03ff" (mpo : Power / 03 : Set_ID / ff : Present situation question)
Response : " 03mpo01" ( Status : Power On)
When the TV with 12th Set_ID wants Volume 34
> svo1234
> 12svo34
Command : " svo1234" (svo : Volume / 12(Dec) : Set_ID / 34(Dec) : Volume size)
Response : " 12svo34" ( Set_ID 12th person PDP Volume 34)
When wanting putting out all the member of all TV
> mpo0000
Command : " mpo0000" (mpo : Power / 00 : All PDP which are connected / 00 : Power)
when it wants to sees Last Command it does not change a set not to be
> ff00100
Command :" ff00100" (ff0 : The Last the Command it asks / 01 : Set_ID / 00 :
3. Communication Table
1) Command structure
C1
P : Picture
S : Sound
M : Setup (Miscellany)
T : TV
Condition question)
C2
C3