14. Set the FREQUENCY (carrier frequency) of the signal
generator as follows :
FREQUENCY (carrier frequency) :
U30 model
; 589.000 MHz
U42 model
; 661.000 MHz
CE62 model
; 821.000 MHz
CE67 model
; 861.000 MHz
KR model
; 751.000 MHz
15. Check first that indication "L" of "AC3L" on the LCD
(URX-P2) has disappeared, and then press the "SET"
button of the URX-P2.
16. Connect the signal generator to the CN101/RF-130
board with the MM-SMA conversion connector and
the RF adjusting cable.
17. Indication on LCD (URX-P2) appears as follows :
LCD :
B C1 L
18. Set the FREQUENCY (carrier frequency) of the signal
generator as follows :
FREQUENCY (carrier frequency) :
U30 model
; 567.000 MHz
U42 model
; 639.000 MHz
CE62 model
; 799.000 MHz
CE67 model
; 839.000 MHz
KR model
; 741.000 MHz
19. Check first that indication "L" of "BC1L" on the LCD
(URX-P2) has disappeared, and then press the "SET"
button of the URX-P2.
20. Indication on the LCD (URX-P2) appears as follows :
LCD :
B C2 L
21. Set the FREQUENCY (carrier frequency) of the signal
generator as follows :
FREQUENCY (carrier frequency) :
U30 model
; 578.000 MHz
U42 model
; 650.000 MHz
CE62 model
; 810.000 MHz
CE67 model
; 850.000 MHz
KR model
; 746.000 MHz
UWP Series
(B C1 L)
(B C2 L)
22. Check first that indication "L" of "BC2L" on the LCD
(URX-P2) has disappeared, and then press the "SET"
button of the URX-P2.
23. Indication on the LCD (URX-P2) appears as follows :
LCD :
B C3 L
24. Set the FREQUENCY (carrier frequency) of the signal
generator as follows :
FREQUENCY (carrier frequency) :
U30 model
; 589.000 MHz
U42 model
; 661.000 MHz
CE62 model
; 821.000 MHz
CE67 model
; 861.000 MHz
KR model
; 751.000 MHz
25. Check first that indication "L" of "BC3L" on the LCD
(URX-P2) has disappeared, and then press the "SET"
button of the URX-P2.
26. Indication on the LCD (URX-P2) appears as follows :
LCD :
BACKUP
FInISH

27. Adjustment is completed. (Normal operation mode)

(B C3 L)
(BACKUP)
(FINISH)