Sony UWP-V1 Service Manual page 43

Uhf wireless microphone package
Hide thumbs Also See for UWP-V1:
Table of Contents

Advertisement

10. Spurious Emissions Check
Equipment and Tools
. DC power supply
DC output voltage : +3.0 ± 0.1Vdc
. DC ammeter
. Spectrum analyzer
. MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
. SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
MB-1137 board
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 42-01 channel (650.125 MHz)
CE62 model ; Group 00, 63-32 channel (810.000 MHz)
CE67 model ; Group 00, 68-32 channel (850.000 MHz)
KR model
; 60-01 channel (746.125 MHz)
Attenuation setting :
Accumulated time setting : "00 : 00"
n
Take note of the settings before starting the confirmation
work.
After confirmation is completed, return the settings to
the original setting before change.
UWP Series
0 dB
Connections
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-2-2.
. For connecting the MIC input connector (CN2), refer to
"4.Reference Frequency Deviation Adjustment".
MM-SMA conversion connector and
SMA-BNC conversion connector
CN101
MB-1137 board (B side)
CN2
Input termination (shorted between GND and HOT)
Procedure
1. Set the spectrum analyzer as below;
CENTER FREQUENCY
REFERENCE LEVEL
FREQUENCY SPAN
RBW (resolution band width) : 300 kHz
ATT
2. Check that the spurious emissions level (up to 3 GHz)
reading for the spectrum analyzer remains below
_40 dBm.
Carrier frequency
Spectrum analyzer
MB-1137 board (B side)
: 1.5 GHz
: 20 dBm (10 dBm ; KR
model only)
: 3 GHz or Full span
(300 MHz/DIV)
: 20 dB
+20 dBm
_40 dBm
v:10 dB/div
H:20 MHz/div
3 GHz
1.5 GHz (fc)
2-23