Displaying the condition of the projector (continued)
: Displays peripheral temperature in Celsius. While the lamp is on,
supplied voltage is also displayed.
3rd line
3rd line: Displays supplied voltage and peripheral temperature in
NOTE
• While the projector is searching an input signal or USB TYPE A ports
are selected in normal condition, nothing is displayed on the 2nd line of the
monitor.
• When the USB TYPE B port is selected even if MOUSE is selected in the
USB TYPE B item of the OPTION menu, "NO SIGNAL" is displayed on the 2nd
line of the monitor (65).
• Displayed temperature might differ from actual peripheral temperature
because the displayed temperature is measured inside of the projector.
 In error state
The Status Monitor displays a warning of an error
with larger letters. Resolve the errors referring to the
table of the sections "Related messages" (117) and
"Regarding the indicator lamps" (118, 119) when the
warning is displayed.
Displayed warnings are as below;
COVER: The lamp cover has not been properly fixed.
Refer to the LAMP indicator blinking in the table (118).
FAN: The cooing fan is not operating.
Refer to the TEMP indicator blinking in the table (119).
LAMP: The lamp does not light.
Refer to the LAMP indicator lighting in the table (118).
TEMP: The projector's interior becomes over heated.
Refer to the TEMP indicator lighting in the table (119).
AIR (AIR FLOW): The internal temperature is rising.
Refer to the description of the message, "CHECK THE AIR FLOW" in the
table (117).
COLD: There is a possibility that the interior portion has become over cooled.
Refer to the LAMP and TEMP indicators alternatively blinking in the table
(119).
FILTR (FILTER): It is time to clean the air filter.
Refer to the LAMP and TEMP indicators simultaneous blinking in the table
(119).
NOTE
• When one of the warnings of FAN, LAMP, COVER, TEMP errors is
displayed, the backlight blinks at the same time.
Status Monitor <Only for CP-X8160, CP-WX8250 and CP-WU8450>
Celsius while the lamp is on.