Specifications - Pro-Tech 7030-7035 Owner's Manual

9 volt battery co alarm, single station. 9 volt battery co alarm with lcd digital display & peak level memory, single station
Table of Contents

Advertisement

CO GAS EXPOSURE VERSUS TIME
(400 PPM EXPOSURE)
MINUTES
8
NONE
15
NONE
25
SLIGHT HEADACHE
35
HEADACHE
45
HEADACHE AND NAUSEA
60
DROWSY
75
VOMITING
90
COLLAPSE
110
COMA AND PERMANENT
BRAIN DAMAGE
140
PERMANENT BRAIN
DAMAGE – DEATH

2. SPECIFICATIONS

CO ALARM RANGE
CO RESPONSE TIME
POWER SOURCE
OPERATING TEMPERATURE
ALARM
DETECTION FREQUENCY
1. LCD DISPLAY (7035):
1. DIGITAL READ-OUT OF CO
DETECTED AND PEAK LEVEL
MEMORY
2. PEAK LEVEL TIME RECORD (THE
TOTAL TIME CO IS DETECTED
WITHIN 10% OF THE PEAK LEVEL)
3. COHb RANGE
(CARBOXYHEMOGLOBIN)
DISPLAY TOLERANCE @ 50% RH,
22°C±3°C IN UPRIGHT POSITION
BATTERY TYPE
RESPONSE
70 PPM AND UP
@ 70 PPM
@150 PPM
@ 400 PPM
9V Battery
32
85 dB AT 10 FEET
SAMPLES EVERY 2 MINUTES
FROM 0 PPM TO 500 PPM, WILL FLASH "500"
IF LEVEL EXCEEDS 500 PPM.
FROM 0 TO 999 MINUTES, WILL FLASH "999"
IF LEVEL EXCEEDS 999 MINUTES.
FROM 0.0% TO 99.9%, WILL FLASH "99.9%" IF
LEVEL EXCEEDS 99.9 %.
± 35% @ 30-500 PPM
ONE YEAR DURACELL MN1604 ALKALINE
BATTERY (7030)
OR LONG-LIFE ULTRALIFE UL9VL LITHIUM
POWER CELL (7035)
- 3 -
400 PPM EXPOSURE
50%
45%
40%
35%
30%
25%
20%
15%
10%
5%
0%
8
15
25
60~240 MINUTES
10~50 MINUTES
4~15 MINUTES
o
o
o
F (0
C) TO 120.2
F (49
35
45
60
75
90
110
MINUTES
o
C)
140

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

70307035