Download Print this page

SBI AC01336 Installation Instructions Manual page 7

Pedestal wood stove fresh air adapter kit

Advertisement

B) Installation of a fresh air intake from the floor to the base of the pedestal
Step 1:
Determine the final location of the stove and mark the dimension of the pedestal on the floor
with tape. Move the stove and perform an opening of 5 1/2 "x 5 1/2" (140 mm x 140 mm)
centered in the floor under the stove.
Pass the 5'' insulated flexible pipe (D) through the opening and attach the end above the floor
to the fresh air adapter (A) with a collar (C). Secure the fresh air adapter (A) to the floor with
four screws (B).
7

Advertisement

loading