If you detect bubbles, there is a leak. Close cylinder valve completely. Retighten the
leaking connection and repeat leak test process.
If the leak cannot repaired permanently, close cylinder valve completely and contact
the customer service department at 1-866-539-2039 or a qualified gas technician.
A SAFE LOCATION FOR THE HEATER
CAUTION
When objects are left under a heater in operation, they will be subject to radiant heat
and might be damaged.
The principal application of this heater is to provide heat to pool and
spa areas, terraces, work areas, etc.
This heater is approved for outdoor use only.
● Provide fresh air ventilation at all times
● Respect minimum clearances to combustibles as shown in figure 11 below.
● Install heater on a leveled, solid and stable ground.
● Do not install in an explosive environment. Keep away from areas from where gas,
vapors or flammable liquids are stored or used.
● In case of high winds, shut-off completely the heater and the cylinder gas valve.
Remove reflector dome.
● Do not move the heater when hot.
CLEARANCES FROM COMBUSTIBLES
Respect clearances as shown:
Sides of reflector : 60 cm
-
Above reflector : 45 cm
-