Trouble Shooting Guide

Problem
AC Mains or Generator power is
connected but "Power" LED will not
illuminate.
Generator voltage too low.
Blown fuse (Generator voltage
too high).
DC charging power is connected but
"Power" LED will not illuminate.
Voltage not within limits.
Bad connection.
Blown fuse.
"Charging" LED keeps flashing.
Discharge button has been
pressed.
Batteries or Charger too hot.
Batteries or Charger too cold.
Batteries over-discharged.
Batteries faulty.
Solutions
Check generator output.
Check generator output and fuses in
AC input socket. Replace if blown.
(Refer Figure 6.)
Refer to Specifications for limits.
Check connection of DC power lead
plug and crocodile clips.
Check fuses in AC input socket.
Replace if blown. (Refer Figure 6.)
If discharge is not required, remove
and replace one battery end cap to
reset Charger.
Batteries will not charge if above
45°C. Place Charger in cool place
and wait for batteries to cool down.
The batteries will not charge if below
0°C. Place batteries and Charger in
warmer place.
Leave in Charger for 1 hour. If
"Charging" LED still flashing,
replace batteries.
Replace batteries.