8.5.
Removal of the MOS SENSOR Unit
When remove the MOS SENSOR unit once (the screw(F) is
loosened even a little), the optical tilt adjustment is
required.
When loosen the screw(F), the optical tilt adjustment is
necessary at the end of assembling.
(Refer to item "9.3.2.")
To prevent the MOS SENSOR unit from catching the dust
and dirt, do not remove the MOS SENSOR unit except
replacing it.
1. Unfix a locking tab.
2. Remove the screw(E).
3. Unfix 3 ribs.
4. Pull out the lens flex from the connector.
5. Pull up the lens flex in the direction of an arrow and
remove the copper sheet.
6. Remove 3 screws(F).
7. Remove the MOS SENSOR unit.
39