S E R V I C E
Technical data
Water pressure
Inlet pressure
Spray pump pressure
Rotations
Spray pump motor
Drain pump motor
Spray arm lower
Spray arm upper
Fan for drying
Spray arms, turning rhythm at alternating spray
system
Turning starts every time with the upper spray arm
Pre wash
Lower arm ~3min, Upper arm ~1min
Main wash Lower arm ~3min, Upper arm ~5min
Intermediate rinse
Lower arm ~2min, Upper arm ~2min
Final rinse Lower arm ~2min, Upper arm ~2min
Service Test program
Lower arm ~30sec, Upper arm ~30sec
Remark: When switching of the main switch or
interrupt the mains during the Test Program runs,
then the alternating of the spray arms change in
the test program to the rhythm of main wash 5/3
min.
Important: To leaf the Test program is possible by
made a break by customer (pushing the start
button for 1.5 sec.)
After finishing the test program (End LED shines
and/or Start LED goes of) must the appliance be
switched off.
If this will not be done, then the next normal wash
will be made with the frequency of the Service
Test Program ~30/30sec.
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Spray arm lower
Sprayarm upper
Shower top
Fan for drying:
Total
Primary air flow
Secondary air flow
Whirlpool Europe
Customer Service
0.3 - 10
bar
0.3
bar
2800
RPM
3000
RPM
30 - 40
RPM
30 - 40
RPM
2500
RPM
208
lmp/l
45 - 65
l/min
16
l/min
1.1
m
4
l/min
~ 33
l/min
~ 27
l/min
~ 8
l/min
900
l/min
210
l/min
780
l/min
ADG 8966 IXM
8542 966 10760
Electrical base data
Voltage
Frequency
Total power
Fuse
Spray pump motor alternating spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Fan for drying
Voltage
Resistance
Heating - 1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
(Temperature of water)
Fuse
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Single electric inlet valve
Voltage
Frequency
Resistance
30.10.2003 / Page 3
Doc. No: 4812 718 19569
220/ 230 V
50
Hz
2.0 - 2.2
kW
10
A
220/ 240 V
125
W
79
60
µ F
4
220/ 240 V
30
W
146
220 - 240 V
141
220/ 230 V
1.87/ 2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
0.0
kΩ
0.5
kΩ
1.0
kΩ
1.4
kΩ
1.8
kΩ
2.3
kΩ
2.6
kΩ
220/ 240 V
50/ 60
Hz
3.76
kΩ

Hide quick links: