CAUTION:
Equipment must be
installed to comply
with applicable federal, state,
and local plumbing/electrical
codes.
CAUTION: Follow
this setup procedure
before attempting
to use this unit. Failure to
follow these instructions can
result in injury and/or void of
warranty.
CAUTION: DO NOT
connect the unit to
hot water supply.
The inlet valve is not rated for
hot water.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO.
6913 Acco Street,
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800/421-6150
Fax: 323/837-2410
Service Manual – WB5N Hot Water Dispenser
Important Safeguards/Symbols
This equipment is designed for commercial use. Any servicing other than cleaning and routine
maintenance should be performed by an authorized Wilbur Curtis Company service technician.
• DO NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, DO NOT open service panels. There are no user
serviceable parts inside.
• Keep hands and other items away from hot areas of the unit during operation.
• Never clean with scouring powders or harsh chemicals.
Symbols:
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
INSTALLATION
This Curtis unit is pre-set and ready to go from the factory.
System Requirements:
• Water Supply 20 – 90 PSI (MINIMUM FLOW RATE of 2 GPM)*
• Electrical: See electrical schematic.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume going to the
machine should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of
two gallons per minute.
NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be
purged from the cartridge prior to connection to equipment. In areas with extremely hard wa-
ter, we highly recommend the use of a Curtis approved water filter. For our full line of filters, please
log on to www.wilburcurtis.com.
NSF requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so
that the unit can be moved for cleaning.
2. This unit must be installed with adequate backflow protection to comply with applicable federal,
state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized,
installed and maintained in accordance with federal, state, and local codes.
3. Connect the unit to electrical outlet with appropriate amperage rating (See serial tag on ma-
chine).
4. Once power has been supplied to the unit, flip the toggle switch to the 'ON' position (located on
the rear of the unit), the water tank will begin to fill. When the water level in the tank reaches the
probe, the heating element will turn on.
5. During the initial setup, the heating tank will reach operating temperature in 60 to 70 minutes
(factory default 204°F).
* Expect flow rate from hot water faucet to be 1 GPM from WB5N and 2 GPM from WB5NL
For the latest specifications and information go to www.wilburcurtis.com
W
C
C
ilbur
urtis
ompany
, i
.
nC
1

Advertisement

loading

Summary of Contents for Curtis WB5N

  • Page 1 Montebello, CA 90640-5403 (factory default 204°F). For the latest information go to * Expect flow rate from hot water faucet to be 1 GPM from WB5N and 2 GPM from WB5NL www.wilburcurtis.com Tel: 800/421-6150 For the latest specifications and information go to www.wilburcurtis.com...
  • Page 2 PROGRAMMING UNIVERSAL CONTROL MODULE (UCM) FUNCTION 1. Press TEMP button for 1 second to check the set point tem- perature. 2. Press TEMP button for 3 seconds to enter heating tank tem- perature programming mode. The temperature in the heating tank is adjustable from 140º...
  • Page 3: Illustrated Parts List

    ILLUSTRATED PARTS LIST ITEM № PART № DESCRIPTION WC-37567K KIT, TOP COVER WB5N & WB5NL WC-37579BLK KIT, TOP COVER WB5NB & WB5NLB BLACK WC-1048-101* PUMP ASSEMBLY, AGITATION (120V) WC-1009-101 PUMP, AGITATION 220V W/CAPACITOR & TERMINALS WC-13046-101 HARNESS ASSEMBLY, DV WB5N & WB5NL...
  • Page 4 ITEM № PART № DESCRIPTION WC-61549-101 COVER, SIDE ACCESS WC-61549-101BLK COVER, SIDE ACCESS BLACK WB5N/NL/5NB/5NLB WC-37568K KIT, FRONT COVER WB5N & WB5NL WC-37578BLK KIT, FRONT COVER WB5NB & WB5NLB (BLACK) WC-43157 GROMMET, RUBBER 0.89” ID WC-43158 BUSHING, PLASTIC 1.375 OD WC-1955...
  • Page 5 ITEM № PART № DESCRIPTION WC-5350 TUBE, Ø1/2” x 1/8” WALL SILICONE (1.5 FT) WC-5502-01* PROBE, WATER LEVEL WC-54339 TANK ASSEMBLY, WB5N WC-54339-101 TANK ASSEMBLY, WB5NL WC-934-04 * HEATING ELEMENT, 220VAC 2500W WC-4394 GUARD, SHOCK HEATING ELEMENT WC-1438-101* SENSOR, TEMPERATURE TANK...
  • Page 6 ELECTRICAL SCHEMATIC...
  • Page 7 ELECTRICAL SCHEMATIC...
  • Page 8: Rough-In Drawing

    WB5N ROUGH-IN DRAWING WB5NL ROUGH-IN DRAWING...
  • Page 9 CLEANING Regular cleaning and preventive maintenance is essential in keeping your hot water dispenser looking and working like new. To clean the hot water dispensing unit and components, prepare a mild solution of detergent and warm water. CAUTION – Do not use cleansers, bleach liquids, powders or any other substance containing chlo- rine.
  • Page 10 Curtis equipment that have not been purchased from the Wilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances: 1) Improper operation of equipment: The equipment must be used for its designed and intended purpose and function.