Tankless Coil Boiler Application - Priority Figure 3a.
Opera�on: 
When any thermostat calls for 
heat, the boiler is given a signal to start.  The 
appropriate circulator is energized only when 
the boiler temperature is above the low limit. 
Priority Opera�on: 
switched to the priority se�ng and is ac�vat‐
ed, all other zones will stop opera�on un�l 
zone 6 is sa�sed. When Zone 6 is not 
switched to priority, all zones will operate 
independently. 
When Zone 6 is 
Jumper Placement:  
between terminals ZC and ZR. Connect termi‐
nal ZC to ZC terminal on the aquastat control. 
Connect terminal ZR to ZR terminal on the 
aquastat control.  Conrm polarity is con‐
sistent between the boiler aquastat and the 
switching relay. 
Power input: 
Connect 120 volt as power 
input to terminals N and H. Neutral wire to 
terminal N. Hot wire to terminal H. 
13 
REMOVE the jumper 