Electrical Installation; A Connector Cap; B Connector Cap - Cedes Safe2+ Operation Manual

Safety light curtain systems
Table of Contents

Advertisement

Safe2+ / Safe4

5.3. Electrical Installation

The emitter and receiver are connected to the ma-
chine control using a 5-wire cable.

5.3.1. A connector cap

For the emitter and the receiver two M12 (for cable -
Ø 3 ... 6.5 mm) an two M16 cable glands (for cable -
Ø 3.5 ... 10 mm) are supplied.
Emitter Tx
24 VDC
0 VDC
Test 1
Test 2
Not connected
Not connected
GND
Reveiver Rx
24 VDC
0 VDC
OSSD 1
OSSD 2
Not connected
Not connected
GND
Figure 16: Terminal block connection
12
1
3)
24 VDC
2
0 VDC
3
1)
2)
4
5
Not connected
6
Not connected
7
GND
1.
Operation with internal test
2.
Test using a relay contact
3.
Test using a PNP output
1
24 VDC
2
0 VDC
3
OSSD 1
4
OSSD 2
5
Not connected
6
Not connected
7
GND
(see also Figure 22)

5.3.2. B connector cap

The B connector cap M12/5-pole plug connector
provides easy connection of a cable assembly. The
plug pin assignment is shown in Diagram 18.
Emitter Tx
Reveiver Rx
+ 24 VDC
Figure 17: M12/5 Pin connector
1) Operation with internal test
2) Test using a relay contact
3) Test using PNP output
Figure 18: Wiring of the connecting cables of the M12/5 Pin
Lumberg connector (Part no. cable: 301 347)
The wiring of such connecting plugs is given in fig-
ure 17 and figure 18.
www.cedes.com
Operation Manual
Test 1
+ 24 VDC
OSSD1
Receiver
© CEDES Safety & Automation AG / June 2008
GND
0V
Test 2
GND
0V
OSSD2
Emitter
1)
2)
3)

Hide quick links: