While spinning, is the frequency of the
water level 248 or more? The frequency can be
checked by pressing the Bio button
and Time Delay button at the same time
on the program.
YES
When pressing Bio button and Rinse + button
and POWER button at the same time after
power off, press the START/PAUSE button 2 times,
is the drum low speed spin?
Is it disconnected, or disassembled?
[White : 3pin ( ), Red:3pin ( ),
Red:3pin ( ), National:4pin ( )]
Is it disconnected, or disassembled?
White : 3pin( ), White:4pin( )]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal:
~
~
~
/
/
YES
Replace the PWB assembly.
NO
NO
NO
23
Check the sensor
(Pressure) or hose
(Sensor).
NO
If the problem is on the
sensor or the hose, replace
the sensor or the hose.
Normal
YES
YES
Correct the connector.
YES
Correct the connector.
NO
Replace the STATOR
ASSEMBLY
(4417EA1002D)