1 Source S1-THEC11NS Owner's Manual page 16

Non-programmable digital thermostat
Table of Contents

Advertisement

OWNER'S MANUAL
Sample Wiring Diagrams
Gas or Electric Heat
2 Wire, 1 Stage Gas Heat
Residential Gas or Millivolt units.
For jumper configuration see page 18.
Factory installed
jumper between
RC and RH
GAS OR
ELECTRIC HEAT
POWER
*
Common wire is optional in all installations. If a common wire is not used the
thermostat must be powered by two AA alkaline batteries. These batteries
must be replaced (page 10) each year or when the Low Battery indicator is
displayed (page 3).
S1-THEC11NS
*
Common wire optional
C
RH
Y
W
G
RC
2 Conductor 18 to 22 gauge
unshielded cable from the
thermostat to the equipment.
Page 16

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for 1 Source S1-THEC11NS

Table of Contents