Warranty

Gemini Scientific Corp. warrants the instrument described herein to be free from defects in material and factory
workmanship for a period of one year, and agree to repair such instruments, which under normal use and service
disclose the defect to be the fault of Gemini Scientific Corp.
Gemini Scientific Corp.'s obligation under this Warranty relates to the original purchaser and is limited to a return of the
purchase price or at the Gemini Scientific Corp.'s sole discretion, to the repair or replacement of the instrument or any of
its parts, which prove to be defective. For this Warranty to be in effect, any material or part alleged to be defective is to
be returned to Gemini Scientific Corp. with our prior written approval, fully insured and transportation prepaid by the
purchaser, within 12 months from date of delivery.
This Warranty shall not apply to an instrument which has been (l) subjected to misuse, negligence, or accident; (2)
connected, installed, operated or adjusted other than in accordance with instructions furnished by the Gemini Scientific
Corp.; (3) repaired, modified or serviced by someone not authorized by the Gemini Scientific Corp., so that in our
judgment on the performance or reliability of the instrument has been impaired.
We reserve the right to make replacement with equivalent merchandise and to make changes at any time in the
specification, design, or construction of the instrument without incurring obligation to make any commensurate changes
in units previously delivered.
Gemini Scientific Corp. assumes no liability for consequential or contingent damages for a defective instrument covered
by this Warranty, failure of delivery in whole or part, or for any other cause. This Warranty and the writing to which it is
attached constitute the understanding of the buyer and seller so that no terms, conditions, or agreement purporting to
modify the terms hereof shall be binding unless made in writing and signed by an authorized agent of the home office of
the Gemini Scientific Corp.

WARNING

!
THE AEROSOL FROM THIS INSTRUMENT MAY BE HARMFUL TO THE HEALTH OF THE OPERATOR IF
PRECAUTIONS ARE NOT TAKEN.
The Model 501-B Aerosol Generator/Smoke detector Analyzer generates an aerosol consisting of a refined NF-Grade white
mineral oil in air. Aerosol concentration at the discharge point of the hose is adjustable from 0 to 45 mg/m 3 (0 to 6 mg/min).
Room air would dilute the discharge quickly. The aerosol smoke is odorless and not visible. Proper precautions to avoid
over exposure such as good ventilation and limited discharge time are recommended. Do not hold end of hose close to face
during aerosol discharge.
The maximum allowable limit under OSHA (Occupational Safety and Health Administration) regulation in an eight-hour
weighted average for oil-based aerosol is 5 mg/m 3 . The RUDOL
TM
White Mineral Oil is approved by the FDA (Food and
Drug Administration) for use on skin and incidental food contact.
To reach the OSHA allowable limit, for example, you need to discharge at the maximum concentration rate (6 mg/min)
into a non-ventilated 14x12x10 feet room for a period of about 50 minutes. However, in typical testing, very little aerosol
is introduced into the room. The normal time per test is only about 30 seconds at 1/4 of the maximum concentration, far
below the OSHA safety limit. However, precaution is necessary to avoid situations where exposure can reach above the
OSHA limit.
THIS INSTRUMENT SHOULD NOT BE USED IN OR NEAR CONCENTRATED OXYGEN ENVIRONMENTS SUCH AS
OXYGEN TENTS OR OPERATING ROOMS IN A HOSPITAL.
THIS EQUIPMENT OPERATES AT VOLTAGE LEVELS THAT CAN BE HAZARDOUS TO OPERATING
PERSONNEL.
The Model 501-B Aerosol Generator-Analyzer for Smoke Detectors operates on a rechargeable 12V Ni-Metal Hydride
battery. This voltage appears at the serial number label and various other points on the chassis. The power of the
instrument should be completely turned off before opening the front panel for filter change or repair. Only qualified
personnel, who are familiar with the location of the voltage and the hazards involved, may open the cabinet with power
circuit energized. When connecting a new battery, make sure to observe correct polarity. Connect the red positive (+)
line to the red positive (+) battery terminal and connect the black negative (-) line to the black negative (-) battery
terminal.