5. TROUBLESHOOTING

Problem
Main switch indicator
light does not switch on
Machine welds badly
Over-heating indicator
light switches on
If the machine's malfunction can not be corrected with these measures, contact the
KEMPPI maintenance service.
© Kemppi Oy 0615
Cause
The machine has no supply voltage
Check supply voltage fuses
Check supply voltage cable and plug
Welding outcome is influenced by several
Check that the earthing clamp is fixed
properly, fixing point is clean, and both
cable and its connections are undamaged
Check the flow of shielding gas from the
tip of the welding torch
Supply voltage is uneven, too low or too
high
The machine has over-heated
Check that cooling air can flow without
obstructions
Machine's volume-capacity ratio has
been exceeded; wait for the indicator
light to switch off
The supply voltage is too low or too high