CLEANING the TOILET
Use Microphor's Micro-Clean Organic Spray
Cleaner, P/N 24542 or equivalent.
NOTE:
Sanitizers like Lysol, Pine-Sol, Hezol or
Ammonia base products should never be used. These
sanitizers when flushed into the treatment tank can stop
the biological action.
product in the Microphor System.
WINTERIZING the TOILET
If the toilet system is taken out of service during freezing
conditions and propylene glycol has not be added to the
water supply, turn off water line to toilet, drain water
tank, flush toilet until no more water flows into bowl.
Flush once more to clear ejection chamber under toilet.
To reactivate: fill water tank, turn on water line and flush
toilet.
When outside temperatures are consistently
above freezing use water only without any additives.
USING the TOILET in FREEZING CONDITIONS
For freeze protection during freezing conditions add
food grade propylene glycol
mix protects to about 12˚F and a 60% mix protects to
about minus 40˚F.
Food grade propylene glycol is
available through chemical dealers everywhere.
Water shut-off valve and tank drain
Note:
Never use ethylene glycol based products in
place of the propylene glycol.
products will shut down the bacteria action when flushed
into the treatment tank. Products advertised to protect
RV water systems cannot be used.
Never use any anti-bacterial
to water supply. A 30%
The alcohol based
UNPLUGGING the TOILET
The system can only decompose human waste and
tissue. Heavy paper towels will not decompose and will
eventually clog the passages in the treatment tank. If
the toilet becomes plugged, a standard plunger can be
used to help unplug the unit. If the toilet is plugged, shut
off the water supply and disconnect the air supply.
Press the flush button several times to bleed off the air
pressure. When air pressure is out of the valve, the
flapper in the bottom of the toilet can be pushed open.
Use the plunger as with any standard toilet. If this does
not clear the toilet the waste line to the treatment tank
may be plugged. To clear the waste line remove flexible
junction just outside toilet cabana and clear with a wire
or flush with a stream of water.
Waste line and water supply line
TOILET AIR LINE COLOR CODE
TROUBLESHOOTING the A/W SEQUENCE VALVE