WATER DRAINAGE METHODS

WATER DRAINAGE (Fig. 20)
When in cooling mode, water from the evaporator will flow into the water pan. When the water reaches the low
level mark, the water pump will start operating and water will flow over the condensor, thus increasing cooling
capacity. When the water in the drain pan rises to the high level mark, the control panel LED displays ʻFtʼ (ʻFull Tankʼ
as mentioned in the section on ʻSELF-DIAGNOSISʼ). The compressor will stop, but the water pump and fan motor
will continue to operate. The compressor will not restart until the water tank has been drained.
Before draining the water tank, take care not to move the air conditioner as water may spill from the water tank
onto the floor.
Turn the air conditioner off using the on/off switch on the unit or remote control. Then drain the water tank by
unplugging the drain outlet and allowing the water to flow onto the drain pan. The drain pan will not hold the full
contents of the water tank. A number of fills of the drain pan are required. It may be easier (after 3 or 4 pans have
been drained in order to avoid accidental spillage when shifting the air conditioner) to wheel the unit outside,
remove the drain plug and drain the water onto the ground.
The water tank is considered sufficiently drained when no more water flows from the drain outlet.
Restart the air conditioner by pressing the on/off button. Ensure that the unit is in COOL or DRY mode. The
compressor will start approximately 3 minutes after the unit is switched on.
NOTE:
To completely drain all water from the water tank, tilt the unit by lifting it slightly upwards from the front
until no more water drains from the outlet.