Vector VEC280 User's Manual & Warranty Information

Vector VEC280 User's Manual & Warranty Information

Rechargeable inflator/spotlight high pressure/high volume inflator combo with 12 volt dc portable power supply

Advertisement

Quick Links

VEC280_Manual_110405
11/4/05
12:09 PM
3. If you suspect a bulb is blown, check the bulb filament. If filament is coiled and
unbroken, the bulb is not blown. If filament is blown, replace bulb.
4. If you suspect the main fuse is blown, check it and, if necessary, replace with a
new 20 amp spade fuse.
SPECIFICATIONS
Spotlight:
12 volt H3, 25 watt bulb
Batteries:
Two maintenance-free, sealed lead acid,
6 volt, 4.5 Ah
AC Adapter:
1000mA, 12 volt high frequency charger
Operating Voltage:
12 volts DC
Page 8
8
Rechargeable
Inflator/Spotlight
High Pressure/High Volume Inflator Combo
with 12 Volt DC Portable Power Supply
USER'S MANUAL
& WARRANTY INFORMATION
IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
www.vectormfg.com
VEC280

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEC280 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vector VEC280

  • Page 1: Warranty Information

    Page 8 3. If you suspect a bulb is blown, check the bulb filament. If filament is coiled and VEC280 unbroken, the bulb is not blown. If filament is blown, replace bulb. 4. If you suspect the main fuse is blown, check it and, if necessary, replace with a new 20 amp spade fuse.
  • Page 2: Important Safety Instructions

    For disposal questions, call toll-free (877) 288-7722. This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in materials and workmanship for one year from the date of purchase without additional charge. The Spotlight Safety warranty does not extend to subsequent purchasers or users.
  • Page 3 Specifications ..........8 INTRODUCTION Congratulations on purchasing the VEC280 Rechargeable Inflator/ Spotlight . This unit features a powerful quartz halogen Spotlight, long lasting, 2-LED Area Light, High Pressure/High Volume Inflator Combo and 12 Volt DC Portable Power Supply.
  • Page 4: Ac And Dc Charging/Recharging

    VEC280_Manual_110405 11/4/05 12:09 PM Page 2 Overview Viewing Battery Charge Status CONTROL PANEL Press the Battery Charge Level pushbutton to display battery status. The Battery LED AREA LIGHT (SEE DETAILED BACKLIT AIR Charge Level Indicator LEDs will light. ON/OFF PUSHBUTTON VIEW BELOW) PRESSURE GAUGE LEDs (from left to right):...
  • Page 5: Using The 12 Volt Dc Accessory Outlet

    VEC280_Manual_110405 11/4/05 12:09 PM Page 4 USING THE 2-LED AREA LIGHT Inflating Products Without a Valve Stem Using the Compressor Inflation of other items requires use of one of the adapters (nozzles). The 2-LED Area Light is operated by the LED Area Light ON/OFF Pushbutton located to the right of the Area Light on the front of 1.
  • Page 6: Care And Maintenance

    Replacement Parts Do not expose battery to fire or intense heat, as it may explode. The quartz halogen bulb and sealed lead acid batteries are available through Vector Manufacturing. A comparable (12 volt H3, 25 watt) bulb may be substituted. These DC Plug Fuse Replacement can also be purchased from popular automotive parts suppliers nationwide.

Table of Contents