secure FIreplace to FlOOr or FraMInG

The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use
two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4)
screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate
different wall thickness.
Framing Members
Nailing Flange
Screws
Nailing Flange
Figure 6 -
Secure Fireplace to Framing Studs
nOte: Fireplace may be installed on top of framing or platform constructed of combustible
materials which do not protrude beyond the face.

FInIshInG MaterIal

nOte: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior
to final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating
of Zero) may be used to cover the black painted face of the appliance. It is permissible to bring
combustible wall board to the top of the standoffs on the top and the sides of the unit. A 300°F
minimum adhesive may be used to attach facing materials to the black surface. If joints between
the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material
(General Electric RTV103 or equivalent) must be used.
78D0011
6"
Screws
FP2430
secure fireplace
never install combustible materials over
front face of fireplace.
Noncombustible Material
WDV Series Gas Fireplace
Nailing Flange
FP2430
9