  • Page 1 Owner’s Manual & Warranty B100 Alpine B110 Blue Sea B130 Camaro B140 Elegance B150 Super Camaro DO NOT RETURN MERCHANDISE DIRECTLY TO YOUR ORIGINAL SELLING STORE. CALL MSPA AFTER SALES SERVICE CENTER FOR ANY PRODUCT QUESTIONS. CONTACT US AT info@the-mspa.com www.the-mspa.com...
  • Page 2: Important Safety Instructions

    Risk of Electric Shock WARNING: If the power cord is damaged, purchase a replacement immediately from the manufacturer, MSpa after sale service center or contact a licensed electrician to replace the cord. WARNING: DO NOT use an extension cord to connect spa tub to the power plug; provide a properly located re- ceptacle.
  • Page 3 WARNING: DO NOT turn on the spa tub when the water is frozen. WARNING: Use only approved spa tub accessories. Use of improper or non-approved accessory will void the manufacturer’s warranty. WARNING: RISK OF ELECTRIC SHOCK - Install at least .5m (5 feet) from all metal surfaces. WARNING: RISK OF ELECTRIC SHOCK - Never operate any electrical appliances when the spa tub is in use or when your body is wet.
  • Page 4: Purchase Information

    PURCHASE INFORMATION Bubble SPA (GS) Style No. B-00B Dark Grey B-0A Blue B-30 Black B-40B Grey B-50 Black (color) Item No. A08080 A0808 A08083 A08073 A08075 Pool Shape Oval Round Round Round Round Seating Capacity Water Capacity 700 Ltr/85 gal. 800 Ltr/  gal.
  • Page 5 INSTRUCTIONS NOTE: Ensure to check all parts are present. A: Aluminium foil top lid and zipper pc B: Control panel set C: Spa pool D: Temp barrier mat (optional) E: Digital lock F: Inflation Hose G: Filter cartridge pcs H: Drainage hose I: Repair kit set J: Manometer...
  • Page 6 To make the control box stands firmly, please use nails to fix the control box onto the floor. Don’t install Mspa onto the lawn as grass may cause air pump damped and rusted which could result the air pump works improperly and will void your warranty.
  • Page 7 If it points to yellow sector, the spa is well inflated. You may fill in water now. To avoid over inflation caused by warm weather or sunshine when leaving mspa for weeks inflated and filled with water in temperature higher than 20°c, please reduce the air pressure to the yellow sector of manometer.
  • Page 8 4. Please reduce the air pressure to the yellow sector of manometer, to avoid over inflation due to warm weather or sunshine etc. after leaving Mspa for weeks inflated. Warning: to avoid function failure and damage to the control system, please do not operate until spa is filled with water to the minimum water mark.
  • Page 9: Power Pack Operation

    POWER PACK OPERATION Warning: to avoid function failure and damage, please do not operate until spa is filled with water to the minimum water mark. It is the owner’s responsibility to make sure the installation conditions are met and the following safety and warning rules are exercised.
  • Page 10 Filter Cartridge should be replaced . The MSpa filter cartridge has a lifetime of approx. 6 weeks even it’s well maintained. If the paper wall in the filter still looks new, it means the filter can be used for a few more weeks. We suggest preparing more than one filter so you can switch between the two filters when one of them is being cleaned.
  • Page 11 5. Tilt the spa until no water flow out to empty the spa completely. DO NOT leave your MSpa full of water if you will be away for awhile and no one can take care of the pool. Drain the water before you leave and deflate the spa pool body a bit.
  • Page 12: Troubleshooting

    Spa checklist before unpack the unit and re-use for the new season: In order to have your MSpa runs smoothly and easily for another new season, make sure you do the fol- low: . Check if there is water in the air pipe. If any water is found, dry the air pipe before operating the spa tub.
  • Page 13 Error code Please cut the power supply off to your Mspa, and then plug in again, make sure the right connection of pin "HEF”,“BB plugs, restart power pack operation. If it still doesn’t work, please contact your country MSpa service center.
  • Page 14 Transportation Prepaid, if requested. All The authorized selling dealer is responsible for all in-field service work carried out on your MSpa® prod- uct. ORPC will not be liable for results or cost of workmanship from unauthorized service persons or deal- ers.
  • Page 15 Any damage caused by clogged, dirty or calcified filters c. Any damage that are purely aesthetic and do not hinder the function of the MSpa d. Any damage to the exterior resulting from improper maintenance or any damage to the exterior attribut able to freight mishandling e.
  • Page 16 After Sales Service Center Address Germany ORPC GmbH Braunstrasse  445 Kiel Germany Tel.: + 49 ( 0 ) 43- 66 95 6 9-0 Fax: + 49 ( 0 ) 43- 66 95 6 9-98 E-mail: service@orpcgmbh.de Website: www.orpcgmbh.de...