Download Print this page
Wolf 808331 Instructions Manual
Wolf 808331 Instructions Manual

Wolf 808331 Instructions Manual

For use with models ctwh30, ctwh36, ih4227, w302418, w302718, w362210-482210

Advertisement

Quick Links

IN-LINE BLOWER
For use with models CTWH30, CTWH36,
W302418, W302718, W362210-482210
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only steel ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when flambe-
ing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe').
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
!
FOR DOMESTIC COOKING ONLY
MODEL 808331
H4227,
I
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such
as an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further information
and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
"MOUNTING OPTIONS"
"WIRING PLATE POSITION"
"DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
"ATTACH POWER CORD TO HOOD"
"USE AND CARE"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
!
!
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 808331 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wolf 808331

  • Page 1 Page 1 MODEL 808331 IN-LINE BLOWER For use with models CTWH30, CTWH36, H4227, W302418, W302718, W362210-482210 READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4. Use an extinguisher ONLY if: TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Page 2 Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 4½” X 18½” Mounting brackets TO 10” ROUND HANGER factory-shipped in TRANSITION KIT BOLT position for ½” ceil- & WASHER ing material. EXTENSION CEILING SPRING...
  • Page 3 Page 3 WIRING PLATE POSITION WIRING BLACK TOP / BACK BLACK OF HOUSING VERTICAL GROUND TO POWER CABLE WIRING PLATE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION 120 VAC LINE IN WHITE (from Wiring plate mounts to side or top of housing. range WHITE hood)
  • Page 4 Page 4 ATTACH POWER CORD TO USE AND CARE HOOD To clean blower assembly: Remove access panel, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft Follow wiring instructions packed with range hood, and adhere to cloth and mild soap or detergent to clean blower discharge area and all local and state codes, and the National Electrical Code.
  • Page 5 MODEL 808332 Page 1 IN-LINE BLOWER For use with models CTWH30, CTWH36, H4227, DD30R, DD36R, DD45R, W30-662418, W30-662718, L28-582212, 36-663418 READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4.
  • Page 6 Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 8” X 12” TO 8” X 12” TO 8” X 12” TO (OUTLET) 10” ROUND HANGER 10” ROUND 10” ROUND TRANSITION KIT BOLT TRANSITION TRANSITION (FEMALE)
  • Page 7 Page 3 WIRING WIRING PLATE POSITION BLACK BLACK EDGE OF HOUSING GROUND TO VERTICAL WIRING PLATE POWER CABLE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION WHITE Wiring plate mounts to side or top of housing. WHITE 120 VAC LINE IN DUCTING OPTIONS (from range hood) Ventilator can be wired from outside of housing.
  • Page 8 Page 4 ATTACH POWER CORD TO USE AND CARE HOOD To clean blower assembly: Remove access panel, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft Follow wiring instructions packed with range hood, and adhere to cloth and mild soap or detergent to clean blower discharge area and all local and state codes, and the National Electrical Code.