Now you can remove the tube
Before assembling the new tube it must be "conditioned".
Connect Pin 3 and Pin 7 to a power supply with 12V DC and adjustable current limiter.
Supply each of the following currents for 3 minutes
:
0,5 A / 1 A / 2 A / 3 A / max current ca. 4 A .
The procedure should be finished after 15 minutes to prevent heat problems