Typical wiring for an Electric G+ Lockset
NoTE: Note for the example below
• The door Closed output is wired to indicate the door is closed / power is on.
• The passage; privacy; and deadlock outputs are wired Normally open
i.e. they will indicate when the state is active. They could be wired
normally closed.
Door Closed
Output
Also note that for an Electric G+ Lockset:
• It is possible to have both the Privacy and Deadlock outputs activated
at the same time.
• If the door is open, or the power to the lockset is disrupted for longer
than 1 minute, the G+ Electric Lockset will stop broadcasting its status
and all outputs will revert to their default status – in the example
above – normally open.
Passage
Privacy
Output
Output
Deadlock
Output