Installation; How To Install The Unit; How To Use The Reversible Inlet Grille - LG R1402 Service Manual

Table of Contents

Advertisement

3. INSTALLATION

3.1 HOW TO INSTALL THE UNIT

1. To avoid vibration and noise, make sure the unit is installed
securely and firmly.
2. Install the unit where the sunlight does not shine directly on
the unit.
If the unit receives direct sunlight, build an awning to shade
the cabinet.
3. There should be no obstacle, like a fence, within 20" which
might restrict heat radiation from the condenser.
4. To prevent reducing performance, install the unit so that
louvers of the cabinet are not blocked.
5. Install the unit a little obliquely outward not to leak the
condensed water into the room (about 1/2" or 1/4 bubble
with level).
6. Install the unit with its bottom portion 30~60" above the floor
level.
7. Stuff the foam between the top of the unit and the wall to
prevent air and insects from getting into the room.
8. The power cord must be connected to an independent
circuit. The green wire must be grounded.
9. Connect the drain tube to the base pan hole in the rear side
if you need to drain (consult a dealer).
Plastic hose or equivalent may be connected to the drain
tube.
3.2 HOW TO USE THE REVERSIBLE
INLET GRILLE
The grille is designed to clean the filter both upward and
downward.
A. BEFORE ATTACHING THE FRONT
GRILLE TO THE CABINET, IF YOU WANT
TO PULL OUT THE FILTER UPWARD;
1. Open the inlet grille slightly (a).
2. Turn inside out the front grille (a).
3. Disassemble the inlet grille from the front grille with
separating the hinged part by inserting a straight type
screw-driver tip (b).
4. Then, rotate the inlet grille 180 degrees and insert the hooks
into bottom holes of the front grille.
5. Insert the filter and attach the front grille to the cabinet.
B. IF YOU WANT TO PULL OUT THE FILTER
DOWNWARD;
The grille is already designed for that way.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
FOAM
COOLED
AIR
- 15 -
1/4 Bubble
Level
FENCE
AWNING
HEAT
RADIATION
About 1/2"
Over 20"
b
(a)
(b)
(c)
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1802R1801hWr-1820Lwn2120bcpLwm1822bcg

Table of Contents