Download Print this page

AD Labs RD26 Owner's Manual page 4

Ad labs rd26 digital to analog converter owner's manual

Advertisement

AD LABS
www.musicaltech.com
Use buttons 1, 2 or 3 to switch between the three inputs (AES/EBU, wireless
USB, SP/DIF). A long press on the current selected source will put the unit in
standby mode, indicated by only a dot being lit on the display. In this mode, the
outputs are muted and the DAC and Sample Rate Converter enter low power mode.
To exit standby mode, press buttons 4 or 5 (Volume Up/Down).
Press buttons 4 or 5 (Volume Up/Down) to adjust the volume level.
Press both buttons 4 and 5 (Volume Up/Down) to switch between normal and
inverted output phase. When the phase is inverted, the text PH. I. is displayed. If
the phase is normal, the text PH. 0 is displayed. When the idle screen reappears,
the selected phase is memorized as the default.
Press button 6 (Filter Selection) to change between the five available output
responses. After a short press on this button, the DAC response is changed and the
current filter number is shown on the screen (F1, F2, F3, F4, F5). When the idle
screen reappears, the selected filter is memorized as the default.
A long-press on button 6 (Filter Selection) allows the user to invert the output
channels. When the channels are inverted (left becomes right and vice-versa), the
text 2CH1 is displayed. If the channels are switched back to normal, the text 1CH2
is displayed. When the idle screen reappears, the selected channel order is
memorized as the default.
Use remote control buttons 14, 15 or 16 to switch between the three inputs.
Press buttons Up/Down to adjust the volume level.
Press button 11 (Filter Selection) to change between the five available output
responses. After a short press on this button, the DAC response is changed and the
current filter number is shown on the screen (F1, F2, F3, F4, F5). When the idle
screen reappears, the selected filter is memorized as the default.
By pressing button 12 (Phase Invert) the user can switch between normal and
inverted output phase. When the phase is inverted, the text PH. I. is displayed. If
the phase is normal, the text PH. 0 is displayed. When the idle screen reappears,
the selected phase is memorized as the default.
Press button 8 (Mute) to force output mute. In this state the idle screen blinks
and can only be disabled by another press of button 8 or unplugging and powering
up the the RD26 unit.
Use button (Standby) to put the unit in standby mode. Use button (Display) to
show the current firmware version.
Technical characteristics:
Inputs : SP/DIF, AES/EBU, USB (wireless)
Outputs : RCA, XLR, Headphones
Input sample rate : 32 - 192 KHz
THD+N : 0.001%
S/N ratio : 120 dB
Variable output : 0 - 4v rms
Output impedance : 32 ohms
Wireless range : 50 m (LOS - line of sight)
RD26