Operation Instructions; Water Supply; Start-Up/Shut-Down Instructions - North Star MA1573001A.1 Owner's Manual

Pressure washer pump
Table of Contents

Advertisement

Water Supply

1.) Make sure the water supply is clean. Debris can cause excess pump wear and reduce performance.
2.) An insufficient water supply will damage your pump. Make sure the water supply is steady and is 20%
over the rated flow of your pump. Use a stopwatch to time how long it takes to fill a 5-gallon bucket with
your garden hose. The bucket must fill faster than the times listed in the table below.
3.) The water supply garden hose must have an inside diameter of at least 5/8". If the hose is more than 100 ft.
long, the diameter must be at least 3/4".
4.) Never use a reservoir tank as a water source. Drawing water out of a tank may cause pump cavitation and
damage to your pump. This pressure washer is designed for a pressurized water source such as a city water
faucet. However, the water source pressure must not exceed 115 psi (8 bar).
Always use a flexible rubber hose for your water supply. Do not use rigid piping.
START-UP INSTRUCTIONS
1. Attach garden hose.
2. Attach pressure hose.
3. Attach gun and lance.
4. Turn water supply ON.
5. Squeeze trigger to
purge air from pump.
6. Insert nozzle.
7. Plug in power cord
8. Reset the GFCI button on the cord
9. Start motor.

Operation Instructions

Model
Time to fill a 5 gal. bucket
A1573001
A1573011
A1573021
A157306
A1575581
Skin puncture hazard.
High pressure fluid can inject under skin resulting in serious injury including
amputation. Do not direct spray at people or animals.
-If skin injection happens, seek IMMEDIATE surgical treatment.
-Do not check for leaks with hand. Instead, use a piece of cardboard to check for
leaks.
-Do not use unit if exterior hose damage is evident. Make sure all fittings are tight
before starting. Relieve system pressure before servicing.
-Know how to stop engine and bleed pressures quickly. Be thoroughly familiar with
the controls.
-Make sure accessories meet the unit's temperature and pressure limits.
-Stop engine and bleed pressures before leaving unit unattended.
167 seconds
167 seconds
100 seconds
100 seconds
125 seconds
SHUT-DOWN INSTRUCTIONS
1. Turn motor OFF.
2. Unplug the power cord.
3. Turn water supply OFF.
4. Squeeze trigger to
relieve system pressure.
5. Remove garden hose.
6. Remove pressure hose.
CONNECTING TO MOTOR
See Specifications section for
motor horsepower, shaft size, and
bolt circle information
WARNING
7
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1573001A1573011A1573021A157306A1575581

Table of Contents