Hoover 7122-01 Instructions Manual

Bath fan with light
Table of Contents

Advertisement

Available languages

Available languages

Hoover is a registerd trademark of Techtronic Industries
Limited and is being used under license by Homewerks
Worldwide, LLC.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-877-319-3757, 8 a.m. - 5 p.m., CST, Monday - Friday.
www.homewerksww.com
BATH FAN WITH LIGHT
MODEL #7122-01
Español p. 11
Dec. 1, 2011

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Hoover 7122-01

  • Page 1 BATH FAN WITH LIGHT MODEL #7122-01 Español p. 11 Hoover is a registerd trademark of Techtronic Industries Limited and is being used under license by Homewerks Worldwide, LLC. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-319-3757, 8 a.m.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Product Specifications ........................2 Package Contents ..........................3 Hardware Contents..........................3 Safety Information ..........................4 Preparation ............................5 New Construction Assembly Instructions ...................6 Existing Construction Assembly Instructions ..................8 Care and Maintenance ........................9 Troubleshooting ..........................9 Warranty ............................10 PRODUCT SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS Airflow: 50CFM Power consumption: 42 W 120V, 60Hz Exhaust fan speed: 1300 rpm...
  • Page 3: Package Contents

    PACKAGE CONTENTS PART DESCRIPTION QUANTITY PART DESCRIPTION QUANTITY Fan unit: body, grille, light 13 watt, GU24 bulb reflector, duct connector HARDWARE CONTENTS (not actual size) Machine Long Wood Washer Washer Screw Screw Qty. 2 Qty. 4 www.homewerksww.com...
  • Page 4: Safety Information

    SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. Always disconnect the power supply prior to servicing the fan, motor or junction box. Installation work must be carried out by a qualified person(s) in accordance to all local and safety codes including the rules for fire-rated construction.
  • Page 5: Preparation

    PREPARATION Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts. Estimated Assembly Time: 60 minutes Tools Required for Assembly (not included): Hammer, Drill Bits, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife...
  • Page 6: New Construction Assembly Instructions

    ASSEMBLY INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. INSTALLATION IN NEW CONSTRUCTION Select the location for the fan in the ceiling. Position housing mounting tabs against joist so that bottom edge of housing is flush with ceiling board.
  • Page 7 ASSEMBLY INSTRUCTIONS Check damper to see that it opens freely. Tape all connections to make them secure and air tight. CONNECT WIRING Wire fan following diagram on page 5. Route electrical cable directly to unit. Cable should not touch sides or top of housing after installing.
  • Page 8: Existing Construction Assembly Instructions

    ASSEMBLY INSTRUCTIONS INSTALLATION IN EXISTING CONSTRUCTION 11. Select the location for the fan in the ceiling. In attic, place mounting tabs against joist. Trace outline of housing on ceiling board. Remove housing and cut ceiling opening slightly larger than marked. Put housing in opening with bottom edge flush with ceiling board.
  • Page 9: Care And Maintenance

    CARE AND MAINTENANCE WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once a year. • Never use solvents, thinner or harsh chemicals for cleaning the fan. • Do not allow water to enter the motor. •...
  • Page 10: Warranty

    LIMITED 5-YEAR WARRANTY If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn.
  • Page 11 BAÑO DEL VENTILADOR CON LUZ MODELO #7122-01 Hoover es una marca comercial registrada de Techtronic Industries Limited y se utiliza bajo licencia de Homewerks Worldwide, LLC. ¿Preguntas, problemas, piezas faltantes? Las preguntas relacionadas con reclamos de la garantía pueden realizarse al 1-877-319-3757, de 8 a. m. a 5 p. m., hora central estándar, de lunes a viernes.
  • Page 12: Especificaciones Del Producto

    TABLE OF CONTENTS Especificaciones del producto ......................12 Contenido del paquete ........................13 Aditamentos............................13 Información de seguridad .........................14 Preparación ............................15 Instrucciones de ensamblaje – INSTALACIÓN EN FABRICACIÓN EXISTENTE ......16 Instrucciones de ensamblaje – INSTALACIÓN EN FABRICACIONES NUEVAS ......18 Cuidado y mantenimiento .........................19 Solución de problemas ........................19 Garantía............................20 ESPECIFICACIONES DEL PRODUCTO...
  • Page 13: Contenido Del Paquete

    CONTENIDO DEL PAQUETE PIEZA DESCRIPCIÓN CANTIDAD PIEZA DESCRIPCIÓN CANTIDAD Unidad de ventilación: el cuerpo, reflector de rejilla, 13 vatios, GU24 Bombilla la luz, conector de conducto ADITAMENTOS (no es el tamaño real) Máquina de Tornillo para Arandela Arandela de tornillo madera largo plana seguridad...
  • Page 14: Información De Seguridad

    INFORMACIÓN DE SEGURIDAD Lea y comprenda completamente este manual antes de intentar ensamblar, usar o instalar el producto. Desconecte siempre el suministro de electricidad antes de realizar tareas de mantenimiento en el ventilador, el motor o la caja de unión. El trabajo de instalación debe estar a cargo de personas calificadas, de acuerdo con todos los códigos locales y de seguridad, incluidas las normas para fabricación con resistencia al fuego.
  • Page 15: Preparación

    PREPARACIÓN ADVERTENCIA: Desconecte la electricidad en la caja del interruptor de circuito antes de comenzar la instalación. Retire con cuidado la unidad de la caja. Antes de comenzar a ensamblar el producto, asegúrese de tener todas las piezas. Compare las piezas con la lista del contenido del paquete y los aditamentos.
  • Page 16: Instrucciones De Ensamblaje - Instalación En Fabricación Existente

    INSTRUCCIONES DE ENSAMBLAJE PRECAUCIÓN: ASEGÚRESE DE DESCONECTAR LA ALIMENTACIÓN AL PANEL DE SERVICIO ANTES DE COMENZAR LA INSTALACIÓN. INSTALACIÓN EN LAS NUEVAS CONSTRUCCIONES Seleccione la ubicación para el ventilador en el techo. Posición de la carcasa de montaje contra la vigueta de pestañas de manera que el borde inferior de la vivienda está...
  • Page 17 INSTRUCCIONES DE ENSAMBLAJE Compruebe amortiguador para ver que se abre libremente. Tape todas las conexiones para que sean seguros y herméticos. CONECTE EL CABLEADO Cable del ventilador en el siguiente diagrama en la página 5. Ruta de cables eléctricos directamente a la unidad. El cable no debe tocar los lados o la parte superior de la vivienda después de la instalación.
  • Page 18: Instrucciones De Ensamblaje - Instalación En Fabricaciones Nuevas

    INSTRUCCIONES DE ENSAMBLAJE INSTALACIÓN EN LA CONSTRUCCIÓN EXISTENTE 11. Seleccione la ubicación para el ventilador en el techo. En el ático, lugar lengüetas de montaje contra la vigueta. Trazar el contorno de la vivienda a bordo de techo. Retire el alojamiento y cortar la abertura del techo un poco más grande que la que señaló.
  • Page 19: Cuidado Y Mantenimiento

    CUIDADO Y MANTENIMIENTO ADVERTENCIA: Desconecte la alimentación antes del servicio. Vea información de seguridad antes de proceder. El mantenimiento de rutina se debe hacer por lo menos una vez al año. • Nunca utilice solventes, disolventes o productos químicos fuertes para limpiar el ventilador. •...
  • Page 20: Garantía

    SOLUCIÓN DE PROBLEMAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA Asegúrese de que una puerta o ventana quede leve o completamente Ingesta insuficiente flujo de aire abierta para permitir el ingreso de flujo dentro de la sala de aire. El ventilador no absorbe aire de la habitación porque no hay suficiente flujo de aire.

Table of Contents