Download Print this page
Aube Technologies TH140-28 Installation Instructions And User Manual
Aube Technologies TH140-28 Installation Instructions And User Manual

Aube Technologies TH140-28 Installation Instructions And User Manual

Advertisement

Quick Links

1. Installation
1.1 Guidelines
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL
Installation should be carried out by an electrician.
• For a new installation, choose a location about 5 ft. (1.5 m)
above the floor.
• The thermostat must be installed facing the heating system and
on an inside wall.
• Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or con-
cealed chimneys or stove pipes.
!
Remove the screw (captive) holding the base to the control
module.
"
Lift the lower part of the module to remove it from the base.
#
Remove the screw (captive) holding the wire cover and remove
the wire cover.
$
Pull wires through the base hole and secure the base to the
wall (or onto an electrical box for line voltage wiring) using the
enclosed wall anchors and screws.
%
Wire the base to the heating system (see section 1.2) and con-
nect the remote input, if necessary (see section 1.3).
&
Once wiring is complete, re-install the wire cover.
'
Use the switches located at the back of the control module to
configure your thermostat (see section 1.4) according to your
application.
(
Install the batteries (see section 1.5).
)
Mount the control module on the base and secure using the
screw.
TH140-28
Electronic Programmable Thermostat
Installation Instructions
and User Guide
SHOCK.
1.2 Thermostat Wiring
NORTH AMERICA
LOW VOLTAGE < 30
V: no polarity
LINE VOLTAGE 120 to 240 VAC
Must be installed onto a certified electrical box.
Connection to a
circulator (pump) of a
water heating system
For a 2-wire
connection: no polarity
For a 3-wire
connection: respect the polarity
Connection to a
circulator through
a 24 V relay
Connection to
the thermostat
terminals of a
furnace
EUROPE
Direct wiring to
the circulator
Connection to the
thermostat termi-
nals of a furnace
Wiring to a
power-operated
mixing control
valve
1/4
400-140-000-A

Advertisement

loading

Summary of Contents for Aube Technologies TH140-28

  • Page 1 1.2 Thermostat Wiring TH140-28 NORTH AMERICA Electronic Programmable Thermostat LOW VOLTAGE < 30 V: no polarity Installation Instructions and User Guide Connection to a 1. Installation circulator through a 24 V relay 1.1 Guidelines TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.
  • Page 2 1.3 Remote Input Wiring Heating Cycle Selection (switches #1 and #2) In proportional adaptive mode, the TH140 adapts the control cycles The TH140 is equipped with a remote input which allows connec- to the system’s capacity. Short cycles help eliminate temperature tion of a telephone controller (optional Aube CT240), a home auto- variations, thus increasing user comfort.
  • Page 3 1.5.1 Replacing the batteries 3. Select the Operating Mode The TH140 will display an icon indicat- ing that the batteries must be replaced. The TH140 offers three operating modes: This icon will be displayed for 60 days; after this delay, the TH140 will shut 3.1 Automatic down the heating unit.
  • Page 4 11:00 11:00 11:00 11:00 AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under To program this schedule: normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged Press PROGRAM.