Aube Technologies TH146-P-U Installation Manual

Aube Technologies TH146-P-U Installation Manual

Aube technologies inc. programmable h/c controller thermostat installation guide
Hide thumbs Also See for TH146-P-U:

Advertisement

TH146-P User Console
* To remove a connector from the control module, pry with a screwdriver.
1. Introduction
1.1
Applications
The TH146-P-U programmable controller can be used with any of
the following heating/cooling systems:
Heat pump
1H1C, 2H1C, 2H2C, 3H1C, 3H2C, 3H3C, 4H2C
1H, 2H, 3H, 1C, 2C, 3C, 1H1C, 1H2C, 2H1C, 2H2C,
HVAC
2H3C, 3H1C, 3H2C, 3H3C
The following devices can be connected to the controller:
air recirculation fan
humidifier
dehumidifier or air exchanger
dual-register meter (dual energy)
remote control device (for the unoccupied mode)
1.2
Supplied Parts
• CT280-3H3C control module
• TH146-P console with two wall anchors and mounting screws
• AC144-03 outdoor temperature sensor (3 m or 10 ft) with mount-
ing clip (see section 2.7)
1.3
Accessories
• RC845 relay (see section 2.4)
• AC146-410 plenum temperature sensor (see section 2.8)
• CT241 telephone controller (see section 2.10)
TH146-P-U
Removable
Connector *
CT280-3H3C Control Module
Removable
Connector *
2. Installation
2.1
Control Module (CT280-3H3C)
Configure the control module according to your type of heating/cool-
ing system using DIP switches on the back of the module.
Heat pump
Install the control module near the heating/cooling system, away
from any heat source.
2.2
User Console (TH146-P)
Install the console in a central location. Avoid locations with air
drafts (e.g., top of staircase or air outlet) or stagnant air (behind a
door). Do not install the console on a wall hiding air ducts nor
expose it to direct sunlight.
NOTE: If this controller replaces an old thermostat, any two of the
wires that were connected to the thermostat can be used to connect
the user console to the control module. The maximum wiring length
is 30 m (100 ft).
400-280-010-B
TH146-P-U

Installation Guide

Programmable H/C Controller
AC144-03 Outdoor
Temperature Sensor
HVAC
5/24/07
1/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TH146-P-U and is the answer not in the manual?

Questions and answers

Summary of Contents for Aube Technologies TH146-P-U

  • Page 1: Installation Guide

    TH146-P User Console * To remove a connector from the control module, pry with a screwdriver. 1. Introduction Applications The TH146-P-U programmable controller can be used with any of the following heating/cooling systems: Heat pump 1H1C, 2H1C, 2H2C, 3H1C, 3H2C, 3H3C, 4H2C...
  • Page 2 • fan limit if gas heating is used (HVAC only) • high pressure protection during defrost cycle (This protection is generally needed for add-on installations only. It is not TH146-P-U needed if the heat pump is not connected to the controller terminal WW.)
  • Page 3: Principles Of Operation

    When the controller is configured for an add-on installa- tion, the heat pump is disabled during auxiliary heating to prevent over- pressure. TH146-P-U • New Installation: In this type of installation, as there is not already a furnace, the auxiliary heat source is installed at the same time as the heat pump.
  • Page 4 Heating unit 1 (24 Vac / 1 A) Heating unit 2 (24 Vac / 1 A) W3/O/B Heating unit 3 (24 Vac / 1 A) Fan (24 Vac / 1 A) TH146-P-U Heat Pump 1H1C 2H1C 3H1C Connect the console between the TH terminals (no polarity)
  • Page 5 Wiring Diagram: 2H1C Heat Pump — New Installation Compressor AC146-410 Auxiliary Heat AC144-03 Dual Energy Reversing Valve CT241 Humidifier Fault Dehumidifier Defrost TH146-P-U 400-280-010-B 5/24/07 5/12...
  • Page 6 Wiring Diagram: 3H2C Heat Pump — Add-on Installation Compressor 1 AC146-410 Compressor 2 AC144-03 Dual Energy Reversing Valve CT241 Fault Humidifier Defrost Dehumidifier Furnace TH146-P-U 400-280-010-B 5/24/07 6/12...
  • Page 7 Wiring Diagram: 3H2C HVAC AC146-410 AC144-03 CT241 Humidifier Dehumidifier TH146-P-U Cooling Unit 1 Cooling Unit 2 Heating Unit 1 Heating Unit 2 Heating Unit 3 400-280-010-B 5/24/07 7/12...
  • Page 8: Configuration Menu

    Dehumidifier type Minimum air √ √ exchange time Note: Only items 1 to 4 are available when the controller is placed in user mode (SW1-1 switch). TH146-P-U Display Options Default 12 Hr / 24 Hr 24 Hr Select the time display format.
  • Page 9: General Setting

    2 and 4 of automatic mode and in unoccupied mode, the fan will run only when heating or cooling is activated. The fan will run continuously the rest of the time TH146-P-U Indicator LEDs Indicator LEDs...
  • Page 10 NOTE: The cooling setpoint is always higher than the heating set- point by a minimum of 1°C (1.8°F). For example, if the cooling set- TH146-P-U point is 22°C (72°F) and you set the heating setpoint to 23°C (73°F), the cooling setpoint will automatically become 24°C (75°F). How- ever, if you raise the heating setpoint to 21°C (70°F), the cooling...
  • Page 11: Humidity Setting

    Select 10 - 90 minutes for a specific duration or On for an indefinite length of time. Press the button. TH146-P-U Manual Deactivation To deactivate the air exchange mode: Press the Hum button until one of the following appears on the screen.
  • Page 12: Warranty

    Toll-free: 1-800-831-AUBE Email: advaube@comintes.com Fax: (450) 358-4650 Email: aube.service@honeywell.com For more information on our products, visit us at: www.aubetech.com ® partner, Aube Technologies As an E NERGY has determined that this product meets the guidelines for energy efficiency. NERGY TH146-P-U...

Table of Contents

Save PDF