Digital Output (Do) - LevelOne FCS-5052 User Manual

3-megapixel day/night poe outdoor network camera
Table of Contents

Advertisement

http://ip_address/ notification.cgi?parameter
ip_address – type the IP address or host name of the HTTP host.
Parameter – type the notification parameter if necessary.
Example
URL - http://192.168.1.1/xxxx.cgi
Message - name1=value1&name2=vlaue2
Result - http://192.168.1.1/xxxx.cgi? name1=value1&name2=vlaue2
Ex:
https://192.168.1.1/notification.cgi?event=MD&camera=FB-100A
Message - Enter the message notification that will be sent when an event is triggered.
Enter the user name and password if necessary.
Click Apply to apply settings or Cancel to cancel changes.

Digital Output (DO)

The DO socket allows the IP camera to send output to an external device. While executing the
DO notification action, the IP camera drives voltage on the connected DO wire to the triggering
voltage level for X number of seconds. The connected external device will then be triggered for
X number of seconds.
Triggered Voltage Level - OPEN or GROUND
Users should select the option according to the specification of their external device.