Dimensions
26-1/8"
(VENT CONNECTION)
25-1/4"
22-9/16"
JUNCTION BOX
LOCATION
ACCESSORY
1/2" DIA THERMOSTAT
WIRE ENTRY
3-15/16"
LEFT HAND GAS
33-5/16"
7/8" DIA. ACCESSORY
11/16"
21-5/8"
BOTTOM INLET
24"
(CASING)
NOTES:
1. Two additional 7/8-in. dia. knockouts are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's
recommendations for equivalent diameters.
3. Minimum return-air opening at furnace.
a. For 800 CFM-16-in. round or 14-1/2 x 12-in. rectangle.
b. For 1200 CFM-20-in. round or 14-1/2 x 19-1/3 in. rectangle.
c. For 1600 CFM-22-in. round or 14-1/2 x 22-1/16-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of
single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom of single side
inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM.
58DLA/DLX
(CABINET
UNIT SIZE
WIDTH)
045-08
14-3/16
045-12
14-3/16
070-08
14-3/16
070-12
14-3/16
070-16
17-1/2
090-14
17-1/2
090-16
090-20
110-12
17-1/2
110-16
110-22
135-16
135-22
24-1/2
155-20
24-1/2
12
28-7/8"
7/8" DIA
ENTRY
24-7/8"
5-1/2"
1-11/16"
A
D
(SUPPLY
WIDTH)
12-9/16
12-9/16
12-9/16
12-9/16
15-7/8
15-7/8
21
19-3/8
21
19-3/8
15-7/8
21
19-3/8
21
19-3/8
21
19-3/8
22-7/8
22-7/8
1) 135 and 155 size furnaces require five-
inch vents. Use a 4-5 inch vent adapter be-
tween furnace and vent stack.
2) See Installation Instructions for complete
installation requirements.
1-9/16"
A
2-9/16"
D
13/16"
F
4-13/16"
8-7/16"
1-7/16"
ALTERNATE
JUNCTION BOX
LOCATION (TYP)
VENT OUTLET
5 PLACES (TYP)
3-3/4"
E
11/16"
E
F
(BOTTOM
(TOP VENT
RETURN WIDTH)
OUTLET)
12-11/16
9-5/16
12-11/16
9-5/16
12-11/16
9-5/16
12-11/16
9-5/16
16-1/8
11-9/16
16-1/8
11-9/16
19-1/2
13-5/16
19-1/2
13-5/16
16-1/8
11-9/16
19-1/2
13-51/6
19-1/2
13-5/16
19-1/2
13-5/16
23
15-1/16
23
15-1/16
AIRFLOW
19"
13/16"
OUTLET
11/16"
1-1/2" DIA.
RIGHT HAND
GAS ENTRY
1/2" DIA. THERMOSTAT
WIRE ENTRY
14-7/8"
7/8" DIA. ACCESSORY
1-1/4"
1"
22-1/16"
SIDE INLET
A03060
VENT
CONNECTION
APPROXIMATE
SIZE
SHIPPING
(see notes 1 & 2)
WT (LB)
4
104
4
107
4
111
4
115
4
126
4
127
4
140
4
146
4
135
4
146
4
152
4 (note 1)
149
4 (note 1)
163
4 (note 1)
170