Output Tube Bias Adjustment

As shipped from the factory, the output
'bias' adjustments are set for a nominal
65mA per KT120 tube. Under these idle
conditions
the
tubes
dissipating approximately 27 watts of
their
60
watt
rating.
operation provides 'enriched' Class AB1,
and will satisfy the most critical listener.
For best results, operate and adjust the
Reference150 at 120VAC. Adjustment
must
be
made
under
conditions after at least 15-20 minutes of
uninterrupted stabilization time.
A digital voltmeter capable of accurate
measurements with 0.lmVDC resolution is
preferred for accurate adjustment (must
have 3
/
digit display). Use the plastic
1
2
alignment tool provided to make the
adjustment. The measurement points are
yellow and black banana test jacks next
to each output tube. Adjust the 'bias'
for a voltage reading of 65mVDC (.065
Volt DC) at the blue bias pot for one of
each output tube pair as follows, noting
the voltage setting of the larger V
number tube in each pair is slaved to
the adjustment setting of its lower V
number companion tube: Adjust V5 for
65mVDC and measure its companion
tube V7 to verify a reading of 57 to
73mVDC.
Repeat
adjusting and measuring V9 to read
65mVDC and verify V11 reads 57-
73mVDC; adjust and measure V6 to
read 65mVDC and verify V8 reads 57-
73mVDC, and finally adjust and measure
V10 to read 65mVDC and verify that V12
reads 57-73 mVDC.
Cooling Fan Speed
Adjustment
The two D.C. cooling fans located at the
rear of the Reference 150 are adjustable
in
speed.
Locate
the
dipswitch under the top cover at the top
near the center of the back panel. For
highest fan speed move both white tabs
on the red dip switch to the upward
position; for medium fan speed move
either one of the tabs to the downward
8  
 
are
each
This
point
of
zero-signal
procedure
by
red
colored
position, and for low fan speed move
both tabs to the downward position. For
maximum cooling and extended tube
life, use the highest fan speed possible.
Be sure to first turn off and unplug the
Reference
150
from
receptacle before unscrewing the top
cover to access the switch. Refasten the
top cover before resuming operation.
Do not operate the Reference 150 with
fans disconnected or if one or both fans
should stop running.

Hour Meter

An LCD hour meter of elapsed tube
operating time can be viewed through
the top cover near the front, mounted
on the right main circuit board. This
displays accumulated hours of vacuum
tube service life. If the amplifier is
unplugged
from
A.C.
accumulated hours are retained. May
be
reset
by
qualified
Contact
Audio
Research
Service for more information about reset
procedure.

Servicing

Because
of its careful design
exacting
standards
of
your Reference 150 amplifier should
normally require only minimal service to
maintain its high level of performance.
Caution:
The Reference 150 amplifier
contains sufficient levels of voltage and
current to be lethal. Do not tamper with
a component or part inside the unit.
Even with the power turned off, a
charge remains in the energy storage
capacitors for some time. Refer any
needed
service
to
Audio Research dealer or other qualified
technician.
Additional
regarding the operation, maintenance
or servicing of your amplifier may be
referred
to
the
Customer
Department
of
Audio
Corporation at 763.577.9700 (CST). When
ordering a service manual from Audio
Research or an authorized dealer, be
sure to identify the serial number on your
amplifier.
its
power
supply,
total
technician.