Maintenance
Figure 20. Power venter assembly
Ref. No.
Description
1
Blower Housing Assembly
2
Speed Nut
3
Motor
4
Washer, Plain
5
Plate Adapter
6
Blower Wheel (see
7
Mounting Bracket (Pressure Switch)
8
Mounting Bracket (Junction Box)
9
Screw, S.T.
10
Screw, Machine (L = 3/4")
11
Nut, Keps (Ext. Lock Washer)
12
Air Pressure Switch
13
Drill Screw
14
Junction Box Cover
Notes:
1. For item No. 6, use counter-clockwise rotation.
2. DO NOT OVERTIGHTEN CELCON NUT! HAND TIGHTEN ONLY! DO NOT USE TOOLS! Approximate 1/3 turn maximum or 8 inch pounds is sufficient from
the point where the tube does not slip in or out.
3. Flue Sizes:
100/175 units: 4" dia. flue outlet Reducer required—to be supplied by installer.
200/250 units: 5" dia. flue outlet (no adapter required).
300/400 units: 6" dia. flue outlet Increaser required—to be supplied by manufacturer.
32
Note
1)
Ref. No.
Description
15
Snap Bushing
16
Relay (Motor)
17
Draftor Stack Assembly
18
Tubing (Aluminum) Formation
19
Male Connector
20
Locknut
21
Hole Plug
22
Pressure Switch Cover
23
Drill Screw
24
Junction Box Base
25
Purge Relay
GMND-SVX01B-EN