intervolt Gen II Maxi Series Installation & Operation Manual

Voltage converter
Hide thumbs Also See for Gen II Maxi Series:

Advertisement

Quick Links

Gen II
Maxi SerieS
Voltage
Converter
Thank you for choosing an interVOLT voltage converter ...
A 24VDC to 12VDC voltage converter is used primarily for connecting auxiliary 12VDC equipment in
a 24VDC wired application. The voltage converter must be sized according to the load connected in
order to ensure good performance, safety and longevity. Listed below are just a few of the features and
benefi ts you have gained in selecting an interVOLT voltage converter.
Intervolt SVC Series Switchmode voltage converters are designed for high demand power requirements
in transport, telemetry, alternative energy applications and the like. They are suitable for powering
a large range of auxiliary 12 VDC equipment including communications, navigation, monitoring,
instrumentation, lighting, refrigeration and much more.
Intervolt SVC's incorporate a range of innovative features including an industry fi rst, micro-processor
controlled operator interface for the control and monitoring of the many SVC functions. This feature is
designed to help trouble-shoot general installation errors and assist in fault fi nding common problems.
Intervolt SVC's are fully protected from typical connection and installation faults by a range of built-in
safety devices. These devices protect the units from reverse connection, short-circuiting, overloading,
high output voltages and high temperatures.
Intervolt SVC's are designed to cope with the demands of the harshest applications and will operate in
high temperature, high humidity environments. They are constructed of quality marine grade materials
and when applied and installed correctly are designed to provide many years of continuous service.
Intervolt SVC's are designed and assembled in Australia and comply with relevant Australian and
international standards for electro-magnetic compatibility (EMC). They are supported by a 100% factory
backed 24 month warranty against faulty components and/or workmanship.
inSTaLLaTiOn & OPeraTiOn
ManUaL
www.intervolt.com
Manufactured by Amelec Australia Pty Ltd
16 Parkinson Lane, O'Connor, WA 6163, Australia
interVOLT is a registered trademark of Amelec Australia Pty Ltd in Australia and various other countries
including the UK and USA and as such is protected by the relevant laws of the country of registration.
© 2010. All rights reserved. The entire contents of this instruction manual shall remain the property of
Amelec Australia Pty Ltd and should not be reproduced without written permission.
OVERVIEW .. ... ... .... . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . . 2
SVC MAXI SERIES GEN II . . . . .. . . . . . . .. . . . . . .. . . . . . . . 2
INSTALLATION ... ... .. . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . 3
NOTICE! . ... ... .... ... .. . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . 3
WIRING . .... ... ... .... . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . . 4
INITIAL SET-UP .. .... . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . 7
OPERATION .. ... .... ... . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . 7
EXTENDED FEATURES .. . . . . . .. . . . . . . .. . . . . . .. . . . . . 9
SCHEMATICS ... ... .... . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . 12
Voltage Converter
Standard Installation – Common Ground . . . . . . .. . . 12
Standard Installation – Isolated Ground .. . . . . . . .. . . 13
Parallel Installation – Common Ground . . . . . . .. . . . . 14
Parallel Installation – Isolated Ground . . . . .. . . . . . . . 15
Battery Charger
Standard Installation – Common Ground . . . . . . .. . . 16
Standard Installation – Isolated Ground .. . . . . . . .. . . 17
Auxiliary
External Alarm Output . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . 18
Remote Switching – minor output connected . . . . . . 18
Remote Switching – manual or automatic control . 19
Remote Switching – with ignition switch control . . . 19
Manual No. MAXISVCG2 R1-0
OPERATOR INTERFACE . . . . . . .. . . . . . .. . . . . . . .. . . . . . 20
INTRODUCTION . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . 20
POWER ICON . . . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . 21
FAN ICON . . . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . .. . 21
TEMP ICON . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . 22
INPUT ICON . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . .. 23
OUTPUT ICON . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . . 24
CHARGE ICON . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . 26
OUTPUT LOAD INDICATOR . . . . .. . . . . . .. . . . . . . .. . . . . 27
OUTPUT VOLTS INDICATOR . . . .. . . . . . .. . . . . . . .. . . . . 27
TROUBLESHOOTING . . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . 28
SPECIFICATIONS . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . . . 30
WARRANTY POLICY . . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . 33
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gen II Maxi Series and is the answer not in the manual?

Questions and answers

Summary of Contents for intervolt Gen II Maxi Series

  • Page 1 Gen II inSTaLLaTiOn & OPeraTiOn Maxi SerieS ManUaL www.intervolt.com Manufactured by Amelec Australia Pty Ltd 16 Parkinson Lane, O’Connor, WA 6163, Australia Voltage interVOLT is a registered trademark of Amelec Australia Pty Ltd in Australia and various other countries including the UK and USA and as such is protected by the relevant laws of the country of registration. Converter ©...
  • Page 2: Installation

    SVC MAXI SERIES GEN II NOTICE! The second generation interVOLT SVC Maxi series voltage converters are the evolution of the The SVC must be properly installed in order to comply with environmental operating considerations and original and renowned SVC models fi rst released in 2001. The GEN II Series is not just a cosmetic the manufacturer’s warranty terms and conditions.
  • Page 3: Initial Setup

    INITIAL SET-UP Auxiliary Terminal Block: The auxiliary terminals are optional and not required for operation of the SVC, however they do provide some One of the major features of the Gen II SVC is the ability to adjust very useful functions. Please refer to pages 9-11 for details of the the output voltage when used as a converter or alternatively, specifi...
  • Page 4: Voltage Converter

    Minor Power Output remote Switching input A low power secondary or minor supply (terminal M) is available for very low current requirements such This input (terminal R) is used to isolate the 12VDC output of the SVC from the 24VDC input remotely using as powering a device with a memory for example.
  • Page 5: Battery Charger

    VOLTaGe COnVerTer VOLTaGe COnVerTer Parallel Installation – Common Ground Parallel Installation – Isolated Ground Output voltage setting MUST be the same for each unit connected in parallel. Output voltage setting MUST be the same for each unit connected in parallel. INPUT AUX.
  • Page 6: External Alarm Output

    aUxiLiarY aUxiLiarY aUxiLiarY aUxiLiarY External Alarm Output Remote Switching – minor Remote Switching – manual Remote Switching – with output connected or automatic control ignition switch control INPUT AUX. OUTPUT INPUT AUX. OUTPUT INPUT AUX. OUTPUT INPUT AUX. OUTPUT +24V –0V +24V –0V +24V –0V +24V –0V...
  • Page 7: Output Icon

    TEMP ICON INPUT ICON The TEMP indicator icon displays two possible fault The INPUT indicator icon displays two possible fault conditions in relation to the operating temperature of the conditions in relation to the input (24V) voltage supply to the SVC, details as follows: SVC, details as follows: 1.
  • Page 8 CHARGE ICON OUTPUT LOAD INDICATOR In the event the battery charging (12V) mode is The OUTPUT LOAD indicator is used to display the value of the selected (see set-up instructions) the CHARGE icon load connected to the 12V output. The indicator consists of fi ve is permanently illuminated in addition to the normal LED bars from 25 to 125% (four green and one amber).
  • Page 9 inTerVOLT SVC Gen ii SerieS SVC241225G2 SVC241235G2 inTerVOLT SVC Gen ii SerieS SVC241225G2 SVC241235G2 Continuous Load Rating @ 40°C 25 Amps 35 Amps Transient Voltage Protection Filtering - Purpose designed circuit Intermittent Load Rating @ 40°C * <125% <125% Over Load/Short Circuit Protection Alarm + Shutdown –...

This manual is also suitable for:

Svc241225g2Svc241235g2