Thank you for choosing an interVOLT isolated power conditioner ...
A 24VDC to 24VDC power conditioner is used primarily for connecting auxiliary 24VDC equipment
in a 24VDC wired application. The power conditioner must be sized according to the load
connected in order to ensure good performance, safety and longevity. Listed below are just a few
of the features and benefi ts you have gained in selecting an interVOLT power conditioner.
Intervolt SPCi Series Switchmode power conditioners are designed for high demand power
requirements in transport, telemetry, alternative energy applications and the like. They are
suitable for powering a large range of auxiliary 24VDC equipment including communications,
navigation, monitoring, instrumentation, lighting, refrigeration and much more.
Intervolt SPCi's incorporate a range of innovative features including an industry fi rst, micro-
processor controlled operator interface for the control and monitoring of the many SPCi
functions. This feature is designed to help trouble-shoot general installation errors and assist in
fault fi nding common problems.
Intervolt SPCi's are fully protected from typical connection and installation faults by a range of
built-in safety devices. These devices protect the units from reverse connection, short-circuiting,
overloading, high output voltages and high temperatures.
Intervolt SPCi's are designed to cope with the demands of the harshest applications and will
operate in high temperature, high humidity environments. They are constructed of quality marine
grade materials and when applied and installed correctly are designed to provide many years of
continuous service.
Intervolt SPCi's are designed and assembled in Australia and comply with relevant Australian and
international standards for electro-magnetic compatibility (EMC). They are supported by a 100%
factory backed 24 month warranty against faulty components and/or workmanship.
Installation & OPERATION
MANUAL
www.intervolt.com
Manufactured by Amelec Australia Pty Ltd
16 Parkinson Lane, O'Connor, WA 6163, Australia
interVOLT is a registered trademark of Amelec Australia Pty Ltd in Australia and various other countries
including the UK and USA and as such is protected by the relevant laws of the country of registration.
© 2012. All rights reserved. The entire contents of this instruction manual shall remain the property of
Amelec Australia Pty Ltd and should not be reproduced without written permission.
Manual No. MAXISPCi24G2 R1-0
Overview . .... ... ... .. . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . . 2
Spci Maxi Series Gen Ii . . . . .. . . . . . .. . . . . . . .. . . . . . .. 2
INSTALLATION . .... ... . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . . 3
Notice! . .... ... ... .... . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . 3
Wiring ... ... ... .... ... . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . 4
Operation ... ... .... ... . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . 7
INITIAL SET-UP .. .... . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . 7
Extended Features . . . . .. . . . . . . .. . . . . . .. . . . . . .. . 9
Schematics .. .... ... .. . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . 11
Standard Installation .. . . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . 11
Parallel Installation .. .. . . . . . .. . . . . . .. . . . . . . .. . . . . . . 12
Standard Installation . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . . . 13
Auxiliary
External Alarm Output . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . 14
Remote Switching – manual control . . .. . . . . . . .. . . . . 14
Remote Switching – automatic control .. . . . . . . .. . . . 15
Remote Switching – with ignition switch control . .. 15
OPERATOR INTERFACE . . . . .. . . . . . . .. . . . . . .. . . . . . . . 16
INTRODUCTION . . . . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . 16
Power Icon . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . . 17
Fan Icon . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . .. 17
Temp Icon . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. 18
Input Icon . . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . . 19
Output Icon . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . .. . . . . 20
Charge Icon . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . . . . . 22
Output Load Indicator . . . . . . .. . . . . . . .. . . . . . .. . . 23
Output Volts Indicator . . . . . . .. . . . . . . .. . . . . . .. . 23
Troubleshooting . . . .. . . . . . .. . . . . . .. . . . . . . .. . . . . 24
Specifications . . .. . . . . . . .. . . . . . .. . . . . . .. . . . . . . .. . . 26
Warranty Policy . . . . . . .. . . . . . .. . . . . . . .. . . . . . .. . . 29
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEN II MAXI Series and is the answer not in the manual?

Questions and answers

Summary of Contents for intervolt GEN II MAXI Series

  • Page 1 16 Parkinson Lane, O’Connor, WA 6163, Australia Conditioner interVOLT is a registered trademark of Amelec Australia Pty Ltd in Australia and various other countries including the UK and USA and as such is protected by the relevant laws of the country of registration.
  • Page 2 NOTICE! The SPCi must be properly installed in order to comply with environmental operating considerations and The second generation interVOLT SPCi Maxi series isolated power conditioners are the evolution the manufacturer’s warranty terms and conditions. of the original and renowned SPCi models fi rst released in 2003. The GEN II Series is not just a cosmetic ‘makeover’...
  • Page 3 INITIAL SET-UP Auxiliary Terminal Block: The auxiliary terminals are optional and not required for operation of the SPCi, however they do provide some very One of the major features of the Gen II SPCi is the ability to adjust useful functions. Please refer to pages 9-10 for details of the specifi c the output voltage when used as a conditioner or alternatively, control and monitoring functions of the auxiliary circuits.
  • Page 4 POWER CONDITIONER Remote Switching Input Standard Installation The SPCi has a special isolation feature which allows the unit to be remotely turned on/off by using a simple (N/O) switch to isolate the output. The switch can be in the form of any normally open (N/O) latching device i.e.
  • Page 5 AUXILIARY AUXILIARY AUXILIARY AUXILIARY External Alarm Output Remote Switching – manual control Remote Switching – Remote Switching – with automatic control ignition switch control INPUT AUX. OUTPUT INPUT AUX. OUTPUT INPUT AUX. OUTPUT INPUT AUX. OUTPUT +24V –0V +24V +24V –0V +24V +24V –0V +24V...
  • Page 6 TEMP ICON INPUT ICON The TEMP indicator icon displays two possible fault The INPUT indicator icon displays two possible fault conditions in relation to the operating temperature of the conditions in relation to the input (24V) voltage supply to the SPCi, details as follows: SPCi, details as follows: 1.
  • Page 7 CHARGE ICON OUTPUT LOAD INDICATOR In the event the battery charging (24V) mode is The OUTPUT LOAD indicator is used to display the value of selected (see set-up instructions) the CHARGE icon the load connected to the 24V output. The indicator consists is permanently illuminated in addition to the normal of fi...
  • Page 8 170mm 110mm 55mm purchase is not provided, and at the discretion of the manufacturer, the warranty shall be 24 months from manufacturer’s date of sale to the merchant from whom the product was purchased. Intervolt’s 24 SPCi242420G2 230mm 110mm 55mm month warranty is subject to the following terms and conditions: The goods must be installed and operated in accordance with the manufacturer’s recommendations and...