2-6: VERTICAL POSITION (RF)
1.
Receive the monoscope pattern.
2.
Using the remote control, set the brightness and contrast
to normal position.
3.
Adjust the VR401 until the horizontal line becomes fit to
the notch of the shadow mask. (Refer to Fig. 2-1)
2-7: VERTICAL SIZE (RF)
1.
Receive the cross hatch signal from the Pattern Generator.
2.
Using the remote control, set the brightness and contrast to
normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and press
the channel button (07) on the remote control to select "V.
SIZE".
4.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on upside and
downside becomes 9 ± 2%.
2-8: VERTICAL LINEARITY (RF)
NOTE: Adjust after performing adjustments in section 2-7.
After the adjustment of Vertical Linearity, reconfirm
the Vertical Position and Vertical Size adjustments.
1.
Receive the monoscope pattern.
2.
Using the remote control, set the brightness, contrast,
to normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (08) on the remote control to
select "V. LINERITY".
4.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on upside
and downside becomes minimum.
2-9: TRAPEZIUM (RF)
1.
Receive the cross hatch signal from the Pattern
Generator.
2.
Using the remote control, set the brightness and contrast
to normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (34) on the remote control to
select "TRAPEZIUM".
4.
Press the VOL. UP/DOWN button on the remote control
until the both vertical lines of the screen become parallel.
ELECTRICAL ADJUSTMENTS
horizontal line
Notch
Shadow mask
Fig. 2-1
2-10: HORIZONTAL PHASE (RF)
1.
Receive the center cross signal from the Pattern Generator.
2.
Using the remote control, set the brightness and contrast to
normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select "H.PHASE".
4.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on right and
left becomes minimum.
2-11: LEVEL (RF)
1.
Connect the AC voltmeter to pin 6 of CP101.
2.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (35) on the remote control to
select "LEVEL".
3.
Press the VOL. UP/DOWN button on the remote control
until the AC voltmeter is 85 ± 2mV.
2-12: SEPARATION 1, 2 (RF, AV)
Please do the method (1) or method (2) adjustment.
Method (1)
1.
Set the multi-sound signal generator for each different L-
ch and R-ch frequency (Ex. L-ch=400Hz, R-ch=2KHz)
and receive the RF.
2.
Connect the oscilloscope to the Audio Out Jack.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (36) on the remote control to
select "SEPARATION1".
4.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the audio output wave becomes a fine
sine wave.
5.
Press the CH UP button once the set to "SEPARATION2"
mode. Then perform the above adjustment 4.
Method (2)
1.
Set the multi-sound signal generator L-ch=1KHz, R-ch
=Non input and receive the RF.
2.
Connect the oscilloscope to the Audio Out Jack (R-ch).
3.
Press the AUDIO SELECT button on the remote control
to set to the stereo mode.
4.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (36) on the remote control to
select "SEPARATION1".
5.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the R-ch output becomes minimum.
6.
Set the multi-sound signal generator L-ch=Non input,
R-ch=1KHz and receive the RF.
7.
Connect the oscilloscope to the Audio Out Jack (L-ch).
8.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (37) on the remote control to
select "SEPARATION2".
9.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the L-ch output becomes minimum.
The output difference of the between with Filter and
without Filter should be more than 25db for both L and R.
D-2