Mid-Continent Instrument MD50 series Installation Manual And Operating Instructions

Static electrical power inverter

Advertisement

Quick Links

INSTALLATION MANUAL AND
OPERATING INSTRUCTIONS
MD50-( ) Series
Static Electrical Power Inverter
REV. D February 24, 2011
MANUAL NUMBER 9017039
MID-CONTINENT INSTRUMENT CO., INC.
th
9400 E. 34
Street N., Wichita, KS 67226 USA
phone 316-630-0101 • fax 316-630-0723 • web www.mcico.com

Advertisement

Table of Contents
loading

Summary of Contents for Mid-Continent Instrument MD50 series

  • Page 1 INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD50-( ) Series Static Electrical Power Inverter REV. D February 24, 2011 MANUAL NUMBER 9017039 MID-CONTINENT INSTRUMENT CO., INC. 9400 E. 34 Street N., Wichita, KS 67226 USA phone 316-630-0101 • fax 316-630-0723 • web www.mcico.com...
  • Page 2 Send your comments to: Mid-Continent Instruments Attn: Technical Publications 9400 E. 34 ST North Wichita, KS 67226 USA Phone 316-630-0101, Fax 316-630-0723 info1@mcico.com www.mcico.com © Copyright 2010 Mid-Continent Instrument Co., Inc. REV. D February 24, 2011 Manual Number 9017039...
  • Page 3 REVISION DETAIL Rev. Date Approved Detail 02/26/10 BAW/JRC Initial release. 07/06/10 BAW/MKN Update Section 2.4 to add limitation statement regarding output. 07/20/10 MKN/BAW Update unit picture with True Blue Power label. 02/24/11 JDS/BAW Added section 3.3.2, and figure 3.4. REV. D February 24, 2011 Manual Number 9017039...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SECTION 1 GENERAL DESCRIPTION INTRODUCTION TECHNICAL SPECIFICATIONS 1.2.1 ELECTRICAL ATTRIBUTES 1.2.2 PHYSICAL ATTRIBUTES 1.2.3 QUALIFICATIONS SECTION 2 INSTALLATION CONSIDERATIONS COOLING EQUIPMENT LOCATION ROUTING OF CABLES LIMITATIONS SECTION 3 INSTALLATION PROCEDURE GENERAL INFORMATION UNPACKING AND INSPECTING CABLE HARNESS 3.3.1 WIRE GAUGE SELECTION 3.3.2...
  • Page 5: General Description

    115VAC. The MD50 series Inverter is FAA certified to TSO C73 and tested to rigorous environmental standards and levels of RTCA DO-160. The small size and light weight in conjunction with its installation flexibility inside or outside the pressure vessel make it an ideal choice for aircraft power needs while reducing the challenges associated with other similar products.
  • Page 6: Cooling

    SECTION 2 PRE-INSTALLATION CONSIDERATIONS COOLING No external cooling is required. The unit is equipped with two internal brushless DC fans. Restriction to airflow can cause overheating of the unit and limit performance or reduce the expected life of the product. Make sure to provide adequate clearance on both ends of the unit with the hexagonal openings to allow for proper circulation.
  • Page 7: Installation Procedure

    SECTION 3 INSTALLATION PROCEDURES GENERAL INFORMATION This section contains interconnect diagrams, mounting dimensions and other information pertaining to the installation of the MD50 Static Inverter. After installation of cabling and before installation of the equipment, ensure that power is applied only to the pins specified in the interconnect diagram. UNPACKING AND INSPECTING EQUIPMENT When unpacking this equipment, make a visual inspection for evidence of any damage that may have incurred during shipment.
  • Page 8 INVERTER OUPUT: Pin B – AC Output 115VAC, 60Hz. Used for powering devices where terrestrial/utility power designations are used, pin B can be connected as “Line” or “Hot”. Pin C – AC Return 115VAC, 60Hz. Used for powering devices where terrestrial/utility power designations are used, pin C can be connected as “Neutral”.
  • Page 9 MD50 28VDC INVERTER ENABLE (always active) Optional 5A Optional 1-2A Circuit Breaker Circuit Breakers Case attached to airframe Optional Ground Fault Indicator 110VAC Outlet(s) (not supplied) (not supplied) MD50 28VDC INVERTER ENABLE (Remote ON/OFF) 3rd Party PROTECTION equipment & OUTLETS (not supplied) Case attached to airframe Notes:...
  • Page 10: Harness Verification

    3.3.3 HARNESS VERIFICATION With the MD50 Static Inverter disconnected, activate the aircraft power bus that supplies the unit and use an multi-meter to verify that aircraft power and ground with appropriate voltage is on the pins within the mating harness. MOUNTING Refer to Section 2: Pre-Installation Considerations in regards to equipment location.
  • Page 11 6.34 3.75 8.15 7.40 6.70 (4X) Ø0.20 10-32 Mounting Holes Connector per MS3102A-18-9P 2.74 FIGURE 3.5 MD50 OUTLINE DRAWING REV. D February 24, 2011 Manual Number 9017039...
  • Page 12 3.75 8.75 NOTE: Mounting adapter can be installed on either end of the unit. FIGURE 3.6 MD50 MOUNTING ADAPTER REV. D February 24, 2011 Manual Number 9017039...
  • Page 13: Operation

    OPERATION ELECTRICAL PERFORMANCE The MD50 series Static Inverter converts a direct current (DC) voltage input to a regulated 115 volt alternating current (VAC) output. The output is controlled to a frequency of 60 Hertz and represents a pure sine wave with minimal distortion. The unit is capable of providing 500 watts to power a variety of aircraft accessories including laptops, personal electronics, onboard systems, and many others.
  • Page 14: Protective Features

    4.2.1 REMOTE ON/OFF The MD50 series Static Inverter incorporates a remote on/off feature that allows the user to enable or disable the output of the unit. By providing a ground on the appropriate pin (See Table 3.3) the user, via a remote mounted switch or similar method, can enable the output of the unit.
  • Page 15: Conformance

    SECTION 5 CONFORMANCE CONTINUED AIRWORTHINESS STATEMENT No periodic scheduled maintenance or calibration is necessary for continued airworthiness of the MD50 series Static Inverter. If the unit fails to perform to specifications, the unit must be removed and serviced by Mid-Continent Instruments or their authorized designee. ENVIRONMENTAL QUALIFICATION STATEMENT NOMENCLATURE: Static Electrical Power Inverter...