Mid-Continent Instrument TRUE BLUE POWER TI1200 Series Installation Manual And Operating Instructions

Mid-Continent Instrument TRUE BLUE POWER TI1200 Series Installation Manual And Operating Instructions

Static electrical power inverter

Advertisement

Quick Links

Installation Manual and Operating Instructions
Model TI1200 Series
Static Electrical Power Inverter
True Blue Power® is a division of Mid-Continent Instrument Co., Inc.
Mid-Continent Instrument Co., Inc.
dba Mid-Continent Instruments and Avionics
9400 E. 34
th
Street N.
Manual Number 9017680
Wichita, KS 67226
Rev G, July 17, 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRUE BLUE POWER TI1200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mid-Continent Instrument TRUE BLUE POWER TI1200 Series

  • Page 1 Installation Manual and Operating Instructions Model TI1200 Series Static Electrical Power Inverter True Blue Power® is a division of Mid-Continent Instrument Co., Inc. Mid-Continent Instrument Co., Inc. dba Mid-Continent Instruments and Avionics 9400 E. 34 Street N. Manual Number 9017680...
  • Page 2 Wichita, KS 67226 USA PH (316) 630-0101 FX (316) 630-0723 All products produced by Mid-Continent Instrument, Co., Inc., including those identified as Mid- Continent Instruments and Avionics or True Blue Power, are designed and manufactured in Wichita, KS, USA.  Copyright 2019 Mid-Continent Instrument Co., Inc.
  • Page 3 Added additional DO-160G section category ratings to Table 5.2. Added 6431200-7 with different connector in Table 1.1 and Table 3.3.1. Updated Figure 4.2 True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 4: Table Of Contents

    Output Power Performance Vs Temperature Output Power Performance Vs Input Voltage Output Power Performance Vs Altitude DO-160G Category Qualifications by Section True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 5: General Description

    The True Blue Power TI1200 series has proven to be modular and adaptable to meet different OEM applications. If you have specific functional needs in a power inverter, inquire with the Mid-Continent Instruments and Avionics sales team.
  • Page 6: Technical Specifications

    -15,000 ft. to +55,000 ft.; See Figure 4.3 Temperature: -55°C to +70°C (-67°F to +158°F); See Figure 4.1 Table 1.4: Qualifications True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 7: Pre-Installation Considerations

    The article may be installed only according to 14 CFR part 43 or the applicable airworthiness requirements. True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 8: Installation Procedures

    Pin E 16 to 24 AWG Unused Pins Pins A, G, H, I Table 3.3.2: Connector Pinouts and Recommended Wire Gauge True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 9: Pin Description Information

    For convenience at each AC outlet, individual circuit breakers of 1 to 5 amps each can be used. If a single pole breaker is used, install the breaker on the AC Output. If True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 10: Considerations For Use With Gfi And Noisy Electronics

    True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 11: Example Wiring Diagrams

    The different connector of the 6431200-7 is not shown in these diagrams. True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 12: Mounting

    Verify the output of the unit at the terminating end of the cable with a multi-meter to ensure proper voltage and polarity. Once verified, installation can be completed and functionality of the remote on/off feature (if used) should be checked. True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 13: Ti1200 Series Outline Drawing

    MS3102A24-12P Fan Air Exhaust at connector End Fan Air Intake at this end of Inverter Figure 3.5 TI1200 Series Outline Drawing True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 14: Operation

    ‐5 Temperature ( Figure 4.1 Output Power Performance vs Temperature 1400 1200 1000 Input Voltage (Volts DC) Figure 4.2 Output Power Performance vs Input Voltage True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 15: Protective Features

    Figures 4.1, 4.2, and 4.3. The TI1200 senses output current pulse-by-pulse to determine a short circuit or over-current situation. True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 16: Over-Current And The 6431200-7

    The two fans provide independent redundancy for protection of the unit in the event that one becomes inoperative. True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.
  • Page 17: Environmental Qualification Statement

    Lightning Direct Effects Category X Icing Category X Category A Flammability Category C Table 5.2: List of DO-160G Category Qualifications by Section True Blue Power ® Manual Number 9017680 Revision G, July 17, 2019 a division of Mid-Continent Instrument Co., Inc.

Table of Contents