CHECK GENERATOR SURROUNDINGS
▲
!
WARNING
Make sure you review each warning in order to prevent fire hazard.
•
Keep area clear of flammables or other hazardous materials.
•
Keep generator at least 3 feet away from buildings or other structures.
•
Only operate generator in a dry, well ventilated area.
•
Keep exhaust pipe clear of other objects.
•
Keep generator away from open flame. No smoking!
•
Keep generator on a stable and level surface.
•
Do not block generator air vents with paper or other material.
BATTERY INSTALLATION (SGX7500 Only)
Recommended Battery
Type:
Capacity (Ah/5hr):
Size (inches):
Battery Cable
(Black)
Battery Cable
(Red)
▲
!
WARNING
Death, personal injury and/or property damage may occur unless instructions are followed carefully.
•
Use battery of recommended capacity.
•
Turn the starter switch to the "STOP" position when mounting or dismounting battery. When mounting battery,
connect the positive (+) cable first and then the negative (-) cable to the battery. Be careful not to short battery
cables. When dismounting battery, disconnect negative (-) cable first.
•
Should the connection be made in an incorrect manner, the generator may be damaged.
•
Tighten bolts and nuts on terminals securely so they will not loosen with vibration.
•
Disconnect battery cables when charging battery.
22
Sealed Lead-acid battery
12V-18Ah
7.13L x 3.03W x 6.58H
Battery Hold
Down Bracket
Battery Box
Gasket
RED CABLE
: To positive (+) terminal
BLACK CABLE
: To negative (-) terminal
Bolt
Washer
Gasket
(Battery Hold Down Bracket)
Lock Nut